MAX 16.0 and NI System Configuration 16.0 Known Issues

Overview

This document contains the MAX 16.0 and NI System Configuration 16.0 known issues that were discovered before and since the previous release. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.

This document contains the MAX 16.0 and System Configuration 16.0 known issues that were discovered before and since the release NI System Configuration 16.0. Not every issue known to NI will appear on this list; it is intended to only show the severe and common issues.

Known Issues by Date

The following items are known issues in MAX 16.0 and NI System Configuration 16.0 KIL sorted by Date.

598531MAX 16.0 shows "Inconsistent IP Settings" for remote systems and is missing local network adapters on the Network Adapters tab for My System
587104Setting time and timezone together fails on Linux ARM cRIOs
586003Installing/Uninstalling Real-Time software components to Real-Time targets in MAX fails when LabVIEW Real-Time Software is installed to path with non-English characters
559781System Configuration Restart.vi throws error -2147220309 after setting a Real-Time target to a static IP address on Mac



IDKnown Issue
598531

Return
MAX 16.0 shows "Inconsistent IP Settings" for remote systems and is missing local network adapters on the Network Adapters tab for My System.
MAX 16.0 shows "Inconsistent IP Settings" for remote systems and is missing local network adapters on the Network Adapters tab for My System.

Workaround: Upgrade to MAX to 16.0.1 using NI System Configuration 16.0.1 or update to the NI System Configuration 16.0.1 Run-Time Engine

Reported Version: 16.0  Resolved Version: 16.0.1  Added: 10/01/2016
587104

Return
Setting time and timezone together fails on Linux ARM cRIOs
When setting the current time and timezone together in MAX or the WIF, a Linux ARM cRIO will fail to correctly set the current time.

Workaround: Save the timezone and time in two different steps or put the target in the UTC timezone, save, and then change both the timezone and time.

Reported Version: 16.0  Resolved Version: N/A  Added: 08/01/2016
586003

Return
Installing/Uninstalling Real-Time software components to Real-Time targets in MAX fails when LabVIEW Real-Time Software is installed to path with non-English characters
Users are unable to install/uninstall Real-Time software components using the Real-Time Software Wizard in MAX when LabVIEW Real-Time Software is installed to a path with non-English characters, such as a path Japanese characters.

Workaround: Install LabVIEW Real-Time Software to default path.

Reported Version: 16.0  Resolved Version: N/A  Added: 08/01/2016
559781

Return
System Configuration Restart.vi throws error -2147220309 after setting a Real-Time target to a static IP address on Mac
When setting a static IP address of a Real-Time target on Mac, Restart.vi throws error -2147220309.

Workaround: After setting the IP address, close the System Configuration session, open a new session and then call Restart.vi on the target.

Reported Version: 14.0  Resolved Version: N/A  Added: 08/01/2016

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.