USB-6356
À partir de $5,603.00
8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device
Présentation
The USB-6356 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6356 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
Articles inclus
- Device
- 3 mm, round, bi-level, optical light pipe (Included only with part number 782260-01)
- 2 m, locking USB cable (Included only with part numbers 781444-01, 782261-01, and 781444-02)
- 12 V, 3 A desktop power supply (Included only with part numbers 781444-01, 782261-01, and 781444-02)
- EMI Supression ferrite (Included only with part number 782261-01)
- Safety, Environmental, and Regulatory documentation
USB-6356 Détails du
Numéros de référence (4) Prix | 781444-01 | 781444-02 | 782261-01 | 782260-01 |
|---|---|---|---|---|
| NI Lead Time | 16-17 weeks | 16-17 weeks | 16-17 weeks | 16-17 weeks |
| Number of Bidirectional Digital Channels | 24 | 24 | 24 | 24 |
| Supported Power Input | — | — | — | — |
| Maximum Number of Single-Ended Analog Input Channels | 0 | 0 | 0 | 0 |
| Number of Counters/Timers | 4 | 4 | 4 | 4 |
| Maximum Number of Differential Analog Input Channels | 8 | 8 | 8 | 8 |
| Analog Input Absolute Accuracy | 2688 μV | 2688 μV | 2688 μV | 2688 μV |
| Analog Input FIFO Buffer Size | 32 MS | 64 MS | 32 MS | 32 MS |
| Maximum Sample Rate | 1.25 MS/s/ch | 1.25 MS/s/ch | 1.25 MS/s/ch | 1.25 MS/s/ch |
| Analog Input Isolation | — | — | — | — |
| Simultaneous Sampling | Yes | Yes | Yes | Yes |
| Enclosed | Yes | Yes | Yes | No |
| Analog Input Resolution | 16 bits | 16 bits | 16 bits | 16 bits |
| Bus Connector | USB 2.0 | USB 2.0 | USB 2.0 | USB 2.0 |
| Front Connection Type | Screw Terminal(1) | Screw Terminal(1) | BNC(20) | Generic (OEM)(2) |
| Number of Analog Output Channels | 2 | 2 | 2 | 2 |
| Maximum Analog Update Rate | 3.33 MS/s/ch | 3.33 MS/s/ch | 3.33 MS/s/ch | 3.33 MS/s/ch |
| Reconfigurable | No | No | No | No |
| Number of Analog Input Channels | 8 | 8 | 8 | 8 |
| Maximum Digital Update Rate | 100 ns | 100 ns | 100 ns | 100 ns |
| Operating Temperature Range | 0 °C to 50 °C | 0 °C to 50 °C | 0 °C to 50 °C | 0 °C to 50 °C |
| Bus Connection | USB 2.0 | USB 2.0 | USB 2.0 | USB 2.0 |
| Current Flow Direction | — | — | — | — |
| Digital I/O Isolation | — | — | — | — |
| Digital I/O Logic Levels | 5 V | 5 V | 5 V | 5 V |
| Maximum Clock Rate | 10 MHz | 10 MHz | 10 MHz | 10 MHz |
| Number of Digital Input Only Channels | — | — | — | — |
| Number of Digital Output Only Channels | — | — | — | — |
| Number of External Clock Inputs | 8 | 8 | 8 | 8 |
| Relay Type | — | — | — | — |
| Signaling Type | Single-Ended | Single-Ended | Single-Ended | Single-Ended |
| Supports Peer To Peer Streaming | — | — | — | — |
| Analog Input Voltage Range | -1 V to 1 V -2 V to 2 V -5 V to 5 V -10 V to 10 V | -1 V to 1 V -2 V to 2 V -5 V to 5 V -10 V to 10 V | -1 V to 1 V -2 V to 2 V -5 V to 5 V -10 V to 10 V | -1 V to 1 V -2 V to 2 V -5 V to 5 V -10 V to 10 V |
| Filtering | — | — | — | — |
| Number of Current Output Channels | — | — | — | — |
| Number of Voltage Output Channels | 2 | 2 | 2 | 2 |
| Analog Output Voltage Range | -10 V to 10 V -5 V to 5 V | -10 V to 10 V -5 V to 5 V | -10 V to 10 V -5 V to 5 V | -10 V to 10 V -5 V to 5 V |
| Output Current Range | — | — | — | — |
| Analog Output Isolation | — | — | — | — |
| Analog Output Resolution | 16 bits | 16 bits | 16 bits | 16 bits |
| Analog Input Maximum Absolute Accuracy | — | — | — | — |
| Description du produit | USB-6356, (8 Simultaneous AI, 24 DIO, 2 AO), 32 MS Memory | USB-6356, (8 Simultaneous AI, 24 DIO, 2 AO), 64 MS Memory | NI USB-6356, X Series DAQ Device with BNC Termination | NI USB-6356, OEM X Series DAQ Device (Board Only Kit) |
USB-6356 Accessoires et logiciels
- Modèle (Numéro de référence)DescriptionImageNuméros de référence compatiblesIEC Power Cord (763830-01)Power Cord, AC, U.S., 125VAC, 15A781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (784686-01)Power Cord, 250V, 10A, China781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (784685-01)Power Cord, 240V, 10A, Korea, Right Angle781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (785626-01)Power Cord, 250V, 10A, Brazil781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (786377-01)Power Cord, AC, JAP, 125VAC, 12A781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (787642-01)Power Cord, AC, Taiwan, 125VAC, 15A781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (779424-01)Power Cord 2.29M, 100 VAC, Japan781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (763067-01)Power Cord, 240V, 10A, Euro, Right Angle781444-01, 781444-02, 782261-01, 782260-01IEC Power Cord (763072-01)Power Cord, 250V, 10A, India781444-01, 781444-02, 782261-01, 782260-01
- Produit (Numéro de référence)DescriptionCas d’utilisation recommandésFlexLogger Professional (785748-3501)FlexLogger Professional, Subscription License, Download
Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.
Key Features
- Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
- Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
- Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
- Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
- Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
- Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
- CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
LabVIEW+ Suite (788509-35)NI LabVIEW+ Suite, Subscription License, DownloadRecommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.
The LabVIEW+ Suite includes the following products:
- NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
- NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
- NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
- NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
- NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
Ressources
Support
Demande de support technique
Vous pouvez demander une réparation, planifier l’étalonnage ou obtenir une assistance technique. Vous devez avoir souscrit un contrat de service.
Communauté NI
Posez vos questions, explorez les solutions et participez aux discussions avec d’autres membres de la Communauté NI.
Base de connaissances
Trouvez des réponses aux questions fréquentes et des astuces de dépannage pour les erreurs courantes, rédigées par les ingénieurs NI.
Formations en ligne
Accédez à des centaines de leçons à suivre à votre propre rythme, des parcours de formation axés sur les applications et commencez avec les tutoriels de configuration des produits.