USB-6229

Numéro(s) de référence:

32 AI (16-Bit, 250 kS/s), 4 AO (833 kS/s), up to 48 DIO USB Multifunction I/O Device

Présentation

The USB-6229 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplifies configuration and measurements.
Numéros de référence (20) Prix
780116-11
780116-12
779810-12
779810-11
780116-06
780116-04
780116-07
780116-03
780116-02
780116-01
779810-06
779810-04
779810-07
779810-03
779810-10
195959-01
780116-09
780116-10
779810-09
779810-01
NI Lead Time
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
16-17 weeks
Number of Bidirectional Digital Channels
—
—
—
—
48
48
48
48
48
48
48
48
48
48
48
—
48
48
48
48
Supported Power Input
—
—
—
—
United Kingdom 240VAC
Universal Euro 240VAC
Japan 100VAC
Australia 240VAC
Swiss 220VAC
United States 120VAC
United Kingdom 240VAC
Universal Euro 240VAC
Japan 100VAC
Australia 240VAC
China 220VAC
—
Korea 220VAC
China 220VAC
Korea 220VAC
United States 120VAC
Maximum Number of Single-Ended Analog Input Channels
—
—
—
—
32
32
32
32
32
32
32
32
32
32
32
—
32
32
32
32
Number of Counters/Timers
—
—
—
—
2
2
2
2
2
2
2
2
2
2
2
—
2
2
2
2
Maximum Number of Differential Analog Input Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Input Absolute Accuracy
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3100 μV
—
3100 μV
3100 μV
3100 μV
—
Analog Input FIFO Buffer Size
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Sample Rate
—
—
—
—
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
250 kS/s
—
—
—
—
—
250 kS/s
Analog Input Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Simultaneous Sampling
—
—
—
—
—
—
—
—
—
No
—
—
—
—
No
—
No
No
No
—
Enclosed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Analog Input Resolution
—
—
—
—
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
—
16 bits
16 bits
16 bits
16 bits
Bus Connector
—
—
—
—
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
—
—
—
—
—
USB 2.0
Front Connection Type
—
—
—
—
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Screw Terminal(1)
Generic (OEM)(2)
Screw Terminal(1)
BNC(30)
Screw Terminal(1)
BNC(30)
Screw Terminal(1)
Screw Terminal(1)
Number of Analog Output Channels
—
—
—
—
4
4
4
4
4
4
4
4
4
4
4
—
4
4
4
4
Maximum Analog Update Rate
—
—
—
—
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
833 kS/s
—
—
—
—
—
833 kS/s
Reconfigurable
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Analog Input Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Digital Update Rate
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Operating Temperature Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bus Connection
—
—
—
—
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
USB 2.0
—
—
—
—
—
USB 2.0
Current Flow Direction
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Digital I/O Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Digital I/O Logic Levels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Maximum Clock Rate
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Digital Input Only Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Digital Output Only Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of External Clock Inputs
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Relay Type
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Signaling Type
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Supports Peer To Peer Streaming
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Input Voltage Range
—
—
—
—
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
—
—
—
—
—
-0.2 V to 0.2 V
-1 V to 1 V
-5 V to 5 V
-10 V to 10 V
Filtering
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Current Output Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Number of Voltage Output Channels
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Voltage Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Output Current Range
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Isolation
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Output Resolution
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Analog Input Maximum Absolute Accuracy
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Description du produit
NI USB-6229 M Series DAQ Device, BNC Term, NI-DAQMX Driver, Brazil
NI USB-6229 M Series DAQ Device, BNC Term, NI-DAQMX Driver, Taiwan (110V)
NI USB-6229 M Series DAQ Device, Screw Term, NI-DAQMX Driver, Taiwan (110V)
NI USB-6229 M Series DAQ Device, Screw Term, NI-DAQMX Driver, Brazil
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, U.K. (240 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, EURO (240 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, Japan (100 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, Australia (240 V)
USB-6229(16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, Swiss (220 V)
USB-6229 (16 Differential Analog Input, 250 kS/s) M Series DAQ Device, BNC, U.S. (120 V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, U.K. (240V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, EURO (240V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, Japan (100V)
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, Australia (240V)
USB-6229 M Series DAQ Screw Term, DAQmx,SignalExpress LE, Chinese
NI USB-6229 OEM M Series, Board Only Kit
USB-6229 M Series DAQ BNC Term, DAQmx, SignalExpress LE, Korean
USB-6229 M Series DAQ BNC Term, DAQmx, SignalExpress LE, Chinese
USB-6229 M Series DAQ Screw Term, DAQmx, SignalExpress LE, Korean
USB-6229 (32 Analog Input, 250 kS/s) M Series DAQ Device, Screw Term, U.S. (120V)

USB-6229 Accessoires et logiciels

  • Produit (Numéro de référence)
    Description
    Cas d’utilisation recommandés
    FlexLogger Professional (785748-3501)
    FlexLogger Professional, Subscription License, Download

    Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.

    Key Features

    • Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
    • Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
    • Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
    • Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
    • Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
    • Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
    • CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
    LabVIEW+ Suite (788509-35)
    NI LabVIEW+ Suite, Subscription License, Download

    Recommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.

    The LabVIEW+ Suite includes the following products:

    • NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
    • NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
    • NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
    • NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
    • NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.

Support