NI Product Compatibility for Microsoft Windows 11

Overview

Use the resources below to learn about what NI software supports Windows 11.

Contents

Considerations for Using NI Software with Windows 11

Software bitness: Windows 11 is a 64-bit operating system and has no 32-bit support; this is the first operating system from Microsoft to not include it. However, you are able to run 32-bit software on a 64-bit operating system. For more detailed information on the difference between Windows 32-bit and 64-bit, see Using NI Products on 32-bit and 64-bit Windows.

Using the Windows 11 Compatibility Tables

NI Software Products are broken down into development software, add-ons and toolkits, and drivers. The versions listed in the table indicate the first compatible version of the software for each bitness that will run on Windows 11.  If there is any question about the compatibility of a piece of software, please refer to the Readme.

  • In the tables below, the column titled 'Windows 11 (Using 32-bit Software)' indicates the first version of 32-bit software that will run within the Windows on Windows (WOW64) emulation layer.    
  • Not supported means the product is not supported on or has not yet been tested on Windows 11 64-bit.  
  • Not applicable means the software bitness for that version of the operating system does not exist or is not a valid configuration. For example, Measurement and Automation Explorer (MAX) or LabWindows™/CVI™ development environments do not have 64-bit versions of the executable, but will work on 64-bit Windows 11. 
  • Products not listed on this page do not support Windows 11.

Software

The following table lists the first version of software compatible with Windows 11 64-bit. For more details on specific versions of software, please refer to the Readme for the version in question.

NI Software

Windows 11

(Using 32-bit Software)

(Using 64-bit Software)

GPIB-Serial Converter Software

19.0

19.0

G Web Development Software

Not applicable

2022 Q3

MeasurementLink

Not Applicable

2023 Q1

mmWave OTA Validation Test Software

Not applicable

Not supported

NI Analog Waveform Editor

Not supported

Not supported

NI Calibration Executive

Not applicable

Not supported

NI DIAdem

Not applicable

2022 Q2

NI Digital Pattern Editor

2022 Q4

2022 Q4

NI FlexLogger

Not applicable

2022 Q2

NI Functional Safety Editor

Not applicable

Not supported

NI Hardware Configuration Utility

Not applicable

2023 Q2

NI I/O Trace

2022 Q3

Not applicable

NI InstrumentStudio

Not applicable

2022 Q3

LabVIEW 32-bit

2022 Q3

Not applicable

LabVIEW 64-bit

Not applicable

2022 Q3

LabWindows/CVI Runtime Engine

2020 f3

2020 f3

LabWindows™/CVI™

2020 f3

Not applicable

NI Measurement & Automation Explorer (MAX)

2022 Q3

Not applicable

NI Measurement Studio

2022 Q3

Not applicable

NI Multisim

Not supported

Not supported

NI Package Builder

2022 Q3

2022 Q3

NI Package Manager

2022 Q3

2022 Q3

NI Requirements Gateway

Not supported

Not applicable

NI Switch Executive

2023 Q1

2023 Q1

NI SystemLink

Not applicable

2022 Q1

NI TestStand

2022 Q4

2022 Q4

NI Ultiboard

Not supported

Not supported

NI Update Service

Not supported

Not supported

NI VeriStand

Not applicable

2021 R3

NI VirtualBench

Not supported

Not supported

NI Vision Builder for Automated Inspection

Not applicable

2020

 

Add-Ons and Toolkits

The following table lists the first version of add-on software compatible with Windows 11 64-bit. For more details on specific versions of software, please refer to the Readme for the version in question.

NI Software

Windows 11

(Using 32-bit Software)

(Using 64-bit Software)

FlexLogger Plugin Development Kit

Not applicable

1.4

NI Automotive Diagnostic Command Set

Not supported

 

Not supported

 

NI Bluetooth Toolkit (Run-Time, Generation, Analysis)

Not supported

Not supported

NI ECU Measurement and Calibration Toolkit

21.5

21.5

NI FM/RDS Measurement Suite

Not supported

Not supported

NI GNSS Simulation Toolkit

Not supported

Not supported

LabVIEW Advanced Signal Processing Toolkit

2022 Q3

2022 Q3

LabVIEW Application Builder

2022 Q3

2022 Q3

LabVIEW Control Design and Simulation Module

 

2022 Q3

 

2022 Q3

LabVIEW Database Connectivity Toolkit

2022 Q3

2022 Q3

LabVIEW Datalogging and Supervisory Control Module

2022 Q3

Not applicable

LabVIEW Desktop Execution Trace Toolkit

2022 Q3

2022 Q3

LabVIEW Digital Filter Design Toolkit

2022 Q3

2022 Q3

LabVIEW Electrical Power Toolkit

21.5

Not Supported

LabVIEW FPGA Module 1

2022 Q3

2022 Q3

LabVIEW FPGA Xilinx ISE 1

Not supported

Not applicable

LabVIEW FPGA Xilinx Vivado 1

2022 Q3

2022 Q3

LabVIEW MathScript Module

2022 Q3

2022 Q3

LabVIEW myRIO Toolkit

Not Supported

Not applicable

LabVIEW OPC UA Toolkit

2022 Q4

2022 Q4

LabVIEW Real-Time Module

2022 Q3

2022 Q3

LabVIEW Report Generation Toolkit for Microsoft Office

2022 Q3

2022 Q3

LabVIEW roboRIO Toolkit

Not supported

Not applicable

LabVIEW Sound and Vibration Toolkit
21.521.5

LabVIEW Unit Test Framework Toolkit

2022 Q3

2022 Q3

LabVIEW VI Analyzer Toolkit

2022 Q3

2022 Q3

NI License Manager

21.8

21.8

LabVIEW Modulation Toolkit

2022 Q4

2022 Q4

NI OPC Servers

Not supported

Not supported

NI-RFmx

2022 Q3

2022 Q3

NI Sound and Vibration Measurement Suite

Not supported

Not supported

NI Spectral Measurements Toolkit

Not applicable

Not applicable

NI Vision Development Module

2022 Q3

2022 Q3

NI WLAN Toolkit

Not supported

Not supported

RFIC Test Software

Not supported

Not supported

Semiconductor Device Control Add-On for InstrumentStudio

Not applicable

2022 Q3

TestScale Soft Front Panel Not applicable 2022 Q4

TestStand Semiconductor Module

2023 Q1

2023 Q1

VCSEL I-V Test Software

Not supported

Not supported

Vehicle Communication ToolkitNot applicable1.1

1 The LabVIEW FPGA Module is supported on Windows 11. However, the Xilinx Compilation tools version used for your NI FPGA device might not be. For details, refer to your device readme.

Hardware Drivers

The following table lists the first version of driver software compatible with Windows 11 64-bit. For more details on specific versions of software, please refer to the Readme for the version in question.

NI Software

Windows 11

(Using 32-bit Software)

(Using 64-bit Software)

Industrial Controller Device Drivers

2022 Q3

2022 Q3

Instrument Design Libraries for Reconfigurable Oscilloscopes

21.5

21.5

LabVIEW Instrument Design Libraries for High-Speed Serial Instruments21.521.5

NI-488.2

21.5

21.5

NI-568x

Not supported

Not supported

NI-5690

Not supported

Not supported

NI-845x

2022 Q3

2022 Q3

NI CompactRIO Device Drivers

2022 Q3

2022 Q3

NI-DAQmx

2022 Q3

2022 Q3

NI-DCPower

2022 Q3

2022 Q3

NI-Digital Pattern Driver

2022 Q3

2022 Q3

NI-DMM

2022 Q3

2022 Q3

NI-ELVISmx

Not supported

 

Not supported

 

NI-Embedded CAN for sbRIO

Not supported

Not supported

NI-FBUS

16.0

Not Applicable

NI-FGEN

2022 Q3

2022 Q3

NI-FlexRIO

2022 Q4

2022 Q4

NI-High Speed Serial

21.5

21.5

NI-HSDIO

2022 Q3

2022 Q3

NI-IMAQ

2022 Q3

2022 Q3

NI-IMAQ I/O

2022 Q3

2022 Q3

NI-IMAQdx

2022 Q3

2022 Q3

NI-Industrial Communications for CANopen

2022 Q4

Not Applicable

NI-Industrial Communications for DeviceNet

2022 Q4

Not Applicable

NI-Industrial Communications for DNP3

14.0.1

Not Applicable

NI-Industrial Communications for EtherCAT (NI-ECAT)

2023 Q1

2023 Q3

NI-Industrial Communications for EtherNet/IP

2022 Q3

2022 Q3

NI-Industrial Communications for IEC 60870-5

16.0.1

Not Applicable

NI-272x Reference VIs

13.0

Not Applicable

NI-Industrial Communications for IEC 61850

15.0

Not Applicable

NI IVI Compliance Package

21.0

21.0

NI MXI-Express BIOS Compatibility Software

21.8

21.8

NI-P2P

21.8

21.8

NI-PXImc

19.0

19.0

NI PXI Platform Services

2022 Q3

2022 Q3

NI PXI-5624R Digitizer Instrument Design Libraries

Not supported

Not supported

NI PXI-5644R/5645R/5646R Instrument Design Libraries (VST)

Not supported

Not supported

NI-RDMA

21.5

21.5

NI-RFSA

2022 Q3

2022 Q3

NI-RFSG

2022 Q3

2022 Q3

NI R Series Multifunction RIO Device Drivers 2

2022 Q4

2022 Q4

NI-SCOPE

2022 Q3

2022 Q3

NI-Serial

21.5

21.5

NI-SLSC

2022 Q3

2022 Q3

NI-SWITCH

2022 Q3

2022 Q3

NI-Sync

2022 Q3

2022 Q3

NI System Configuration

2022 Q3

2022 Q3

NI-USRP

21.0

21.0

NI-VISA

2022 Q3

2022 Q3

NI-VRTS

2022 Q3

2022 Q3

NI-VXI

16.0

16.0

NI-XNET

2022 Q3

2022 Q3

PXIe-7899 API and Design Files

Not supported

Not supported

RMX-410x Power Supply Driver

2022 Q3

2022 Q3

Was this information helpful?

Yes

No