The LEDs may not light until the module has been configured in MAX. Before proceeding, verify that the PXI/PXIe/PCI-5122 appears in MAX. If the ACCESS LED fails to light after you power on the chassis, ...

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

In the MAX configuration tree, expand Devices and Interfaces . Expand the Chassis tree to see the list of installed hardware, and press to refresh the list. If the module is still not listed, power ...

Power off and unplug the computer. Access the computer system expansion slots. This step might require you to remove one or more access panels on the computer case. Locate a compatible slot and remove ...

Caution To prevent damage to the PXI/PXIe/PCI-5122 caused by ESD or contamination, handle the module using the edges or the metal bracket. Ensure the AC power source is connected to the chassis before ...

You must be an Administrator to install NI software on your computer. Install an ADE, such as LabVIEW or LabWindows™/CVI™. Insert the driver software media into your computer. The installer should open ...

Self-calibration is done on software command. The calibration corrects for gain, offset, frequency response, triggering, and timing adjustment errors for all input ranges.

3 2 1 4 NI PXI/PXIe/PCI-5122 Driver Software DVD NI PXI/PXIe/PCI-5122 Getting Started Guide Maintain Forced-Air Cooling Note to Users Parent topic: Unpacking the Kit

Launch LabVIEW. Select Help » Find Examples . Open the example VI that you want to use by selecting Hardware Input and Output » Modular Instruments » NI-SCOPE (High-Speed Digitizers) . Tip If you are not ...

Connect CH 0 to an input signal. Launch the NI-SCOPE SFP from the Start menu. In the Select Device dialog box, select the device name assigned to the device in MAX. Click Auto to adjust the acquisition ...

You can make a measurement interactively using the NI-SCOPE SFP or programmatically using LabVIEW. Parent topic: Oscilloscopes GSG Purpose

Restart the system. Launch MAX, and perform the self-test again. Power off the chassis. Reinstall the failed module in a different slot. Power on the chassis. Perform the self-test again. Parent topic: ...

Examples demonstrate the functionality of the device and serve as programming models and building blocks for your own applications.

Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the PXI/PXIe/PCI-5122 . To access PXI/PXIe/PCI-5122 documentation, including ...

You must configure the RTSI cable by completing the following steps: Connect an RTSI cable between the PCI devices to physically share triggers and/or clocks. Launch MAX. In the MAX configuration pane, ...

Operating Environment Ambient temperature range 0 °C to 45 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2 .) Relative humidity range 10% to 90%, noncondensing (Tested in accordance with ...

Operating Environment Ambient temperature range 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2 .) Relative humidity range 10% to 90%, noncondensing (Tested in accordance with ...

Ensure that the environment in which you are using the PXI/PXIe/PCI-5122 meets the following specifications.

You can acquire data interactively using the NI-SCOPE SFP , or you can use the NI-SCOPE instrument driver to program your device in the supported ADE of your choice. Table 3. PXI/PXIe/PCI-5122 Programming ...

You must identify the PXI/PXI Express system controller by completing the following steps: Launch MAX. In the MAX configuration pane, expand the chassis tree. Right-click the name of the chassis you are ...

Operating Environment Ambient temperature range 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2 . Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 ...

The NI website is your complete resource for technical support. At ni.com/support , you have access to everything from troubleshooting and application development self-help resources to email and phone ...

To use the PXI/PXIe/PCI-5122 , your system must meet certain requirements. For more information about minimum system requirements, recommended system, and supported application development environments ...

If you receive an over-temperature or thermal shutdown error and your device shuts down, complete the following steps to re-enable your device: Power off the computer or chassis that contains the device. ...

Caution To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. Touch the antistatic package ...

Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX informs other programs about which devices reside in the system and how they are configured. MAX is automatically installed ...

Figure 3. PXI/PXIe/PCI-5122 Front Panels ACCESS ACTIVE CH 0 CH 1 CH 1 CH 0 TRIG TRIG AUX I/O AUX I/O +5 V MAX 5 V MAX CLK IN CLK IN CLK OUT CLK OUT Table 1. PXI/PXIe/PCI-5122 Front Panel

Skip to Content BookmarksWatch ListSearch PreferencesLog in NI High-Speed Digitizers Getting Started Guide • Last Updated: 2022-04-30 • Tags:  ○ Getting Started ○ USB-5133 ○ USB-5132 ○ PXIe-5622 ○ PXIe-5186 ...

This is the Letter of Volatility for the PCI/PXI/PXIe-5122.