This document contains the SystemLink 20.0 known issues that were discovered before and since the release of SystemLink 20.0. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
966801 |
Asset self-calibration status does not update after unlocking a locked systemAttempting to start an asset self-calibration on a locked system will correctly show "System Locked (changes suspended)" under Status. If the system is subsequently unlocked, the status will change to "Self-Calibrating" but will not update further. This issue is cosmetic only, and the self-calibration completes correctly.
Workaround: Run the self-calibration again with the system unlocked to reset the status.
|
Reported Version: SystemLink: 20.0 Resolved Version: N/A Added: Feb 27, 2020 |
|
972321 |
Querying TDM Reader for multiple files by ID may error on large requestsThe Web Server logs shows the following error: Service for routing key [Skyline.TDMReader] did not respond within the timeout of 30000 milliseconds.
Workaround: Reduce the number of files requested in a single query to avoid a timeout.
|
Reported Version: SystemLink: 20.0 Resolved Version: N/A Added: Feb 27, 2020 |
|
211182 |
Using the browser navigation buttons does not correctly change a queryOn pages with a query panel (Assets, Calibrated Assets, Reports, etc.), the browser back button does not work as expected. When a user presses the back button, the URL in the browser changes, but the filters do not.
Workaround: Remove the filter using the X button next to the property selection field instead.
|
Reported Version: SystemLink: 19.5 Resolved Version: N/A Added: Feb 27, 2020 |
|
959907 |
Test results group by selection is ignored when a filter is changedThe Test Monitor test results table allows grouping results by property. When a user selects a group by property and adds a filter, the group by behavior is incorrect. Results are shown separately instead of grouped.
Workaround: Select a different property to group by and then re-select the original property to reset the table.
|
Reported Version: SystemLink: 19.6 Resolved Version: N/A Added: Feb 27, 2020 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.
Explore Support Content and Product Documentation
Ask the NI Community
Request Support from an Engineer
A valid service agreement may be required, and support options vary by country