2015 f2 Bug Fixes
The following list describes issues in previous versions of the NI Vision Builder for Automated Inspection that are fixed in the 2015 f2 update.
ID | Fixed Issue |
---|---|
617482, 629760 | On NI CVS-1458RT, IC-3120, and IC-317x Linux Real-Time targets, Ethernet interfaces do not always enumerate with the expected name order upon boot. |
608370, 629758 | On NI CVS-1458RT, IC-3120, and IC-317x Linux Real-Time targets, communication with the host does not by default get sent out the primary/host Ethernet port if the host and other devices are all connected with link-local addressing (LLA). |
626575, 629757 | On NI CVS-1458RT, IC-3120, and IC-317x Linux Real-Time targets, devices connected with link-local addressing (LLA) can sometimes obtain duplicate IP addresses upon link negotiation. |
2015 f1 Bug Fixes
The following list describes issues in previous versions of the NI Vision Builder for Automated Inspection that are fixed in the 2015 f1 update.
ID | Fixed Issue |
---|---|
562981 | On real-time targets, timestamp metadata from acquired images may have the UTC offset incorrectly applied to them. |
572339 | You must install Industrial Controller Device Drivers to discover industrial controller targets in LabVIEW projects and to access their shared variables. |
576529 | Vision Builder AI can sometimes hang when exiting the Calculator step. |
577667 | Geometry step results may be mismatched when referring to missing measurements from a previous step. |
583042 | Network drive mounting on Linux RT targets is not successful if /mnt folder does not exist. |
587709 | The Detect Defects step returns a larger defect area than expected when regions to ignore are added to the template and then later removed. |
591218 | You cannot set a password for Configuration Interface access. |
2015 Bug Fixes
The following list describes issues in previous versions of the NI Vision Builder for Automated Inspection that are fixed in the 2015 release.
ID | Fixed Issue |
---|---|
353860 | In the Calculator step, the AltGr key cannot be used to input symbols into a formula node. |
429533 | Color calibrated images are converted to monochrome when saved to file. |
507095, 570862 | The Run LabVIEW VI step sometimes shows a dialog to update other steps in cases where it is not needed. |
518331 | The 1D Barcode step does not handle the Validate option correctly when multiple barcode types are used in a single step. Some types do not support validation. |
520201 | The Run LabVIEW VI step does not let you set a latched Boolean. |
523349 | The Read/Write Variables to INI File step can sometimes swap values for variables with similar names. |
527484 | The Run LabVIEW VI step sometimes does not update references when files have changed on the disk since last load. |
538617 | Image acquisition timeout received when multiple states in the inspection contain acquisition steps with different window sizes or positions. |
541229 | The Run LabVIEW VI step does not allow you to use relative paths when the only common portion of the path is the root of the drive. |
542652 | Inspections do not give a save prompt when migrated between 32-bit and 64-bit instances of Vision Builder AI. |
542944 | Setting a password on a CVS-1457RT blocks access to the target from 64-bit Vision Builder AI applications. |
545859 | In the Acquire Image step, the camera name as seen in MAX is not visible when selecting cameras. |
549194 | After generating LabVIEW VIs with Vision RIO steps, the hardware state is not properly reflected in the Vision RIO test panel. |
552394 | The transition dialog for a state does not allow you to select a specific numeric value greater than 0 if the dialog was using a previous measurement result as the comparison value. |
552682 | System images created for Linux RT-based Compact Vision Systems cannot be redeployed to those targets. |
552910 | The Run LabVIEW VI step does not fail after you rename indicators which are used to set inspection variables. |
553921 | In the Calculator step, controls placed inside a structure do not correctly pass on their values. |
563565 | The context help window can get stuck in a state where it fails to close when expected or to update its content. |
564701 | The system variable Memory Usage reports 0 MB on RT targets. |
565038, 565142 | Extracting part of a calibrated image can return negative areas for particles. |
565352 | A VI resetting dialog is sometimes shown when closing Vision Builder AI. |
568678 | The system variable Device Name does not get properly set on Linux RT targets. |
568683 | Linux RT targets sometimes show inconsistent IP addresses between the Global Variable Manager and the targets' Network Configuration dialog. |
568943 | Large inspections can sometimes return that an error occurred at an unidentified location. |
569019 | Custom steps using advanced math cannot run on Linux RT targets. |
569425 | The NI-DAQmx I/O Test Panel and Monitor cannot set the radix representation (decimal or hexadecimal) of the output port's value. |
569638 | Keyboard shortcuts which close VI diagram windows can accidentally be used in the Calculator step and Custom Inspection Interface in 64-bit instances of Vision Builder AI. |
569658 | Some Vision Assistant steps which modify images incorrectly restrict you from changing the ROI in subsequent steps. |
570861 | Migrating the Run LabVIEW VI step from a previous version of Vision Builder AI returns an error regarding copying files to nonexistent paths. |
571282 | The FTP server is not available for use on Linux RT targets. To use this feature in Vision Builder AI 2015, you must install a recommended software set for Vision Builder AI to the target from MAX, and select the Legacy FTP Server as an optional add-on. |
574248 | When modifying execution flow, copies of other steps can unexpectedly replace inspection steps. |