ID | Known Issue | |||||
---|---|---|---|---|---|---|
346602 | Switching from Ref In to Clk In when there is no signal on Clk In for the NI PXIe-5673E causes the device to enter an unknown state If you configure the NI PXIe-5673E to use the Ref In as the Reference Clock source then change the Reference Clock source to Clk In, a message prompts you to connect a clock source to Clk In of Arb. When you cancel the message, the following error results: Error: The AWG reported the following error: PLL could not phase-lock to the external reference clock. Make sure your reference clock is connected and that it is within the jitter and voltage specifications. Changing a parameter value clears the error message, but the device remains in an error state. Workaround: Click the Preset button or close and reopen the device session.
| |||||
369497 | Incorrect behavior occurs when you load an I/Q file with invalid arguments Loading an I/Q text file with an incorrect array type may force the NI-RFSG SFP to close the current device session or cause the RF On/Off button to stay ON as the NI-RFSG SFP returns an error. If you click the RF On/Off button, the error is removed, but no output signal is generated. Workaround: Reopen the session if needed, then load the I/Q file, or disable Arb mode to generate a signal at the output.
| |||||
372625 | NI-RFSG SFP does not clear PLL lock errors When disconnecting an external Reference Clock, the NI-RFSG SFP returns an error. When you reconnect an external Reference Clock, you must change a setting on the NI-RFSG SFP, such as the frequency setting, in order for the NI-RFSG SFP to attempt to sync to the Reference Clock. Workaround: N/A
| |||||
450527 | An error occurs when you re-enable Arb mode after saving the NI-RFSG SFP configuration When the NI-RFSG SFP is generating in Arb mode and you save the configuration, disabling and then re-enabling Arb mode returns an error. The NI-RFSG SFP continues to generate a signal as if Arb mode is disabled. Workaround: Reload the I/Q file to clear the error, or toggle the RF On/Off button to clear the error.
| |||||
345543 | The splash screen disappears before the NI-RFSG SFP finishes launching When you launch the NI-RFSG SFP and select a device, there may be a delay of five or more seconds after the splash screen disappears and before the SFP appears. Workaround: N/A
| |||||
344365 | Help»NI-RFSG SFP Help opens the Devices topic in the NI RF Signal Generators Help When you select Help»NI-RFSG SFP Help, the help viewer opens to the Devices topic of the NI RF Signal Generators Help. Workaround: Select Help»NI-RFSG SFP Help. In the Contents tab of the NI RF Signal Generators Help, open the NI-RFSG Soft Front Panel Help book, located below the Devices book, to view the Soft Front Panel help.
|