NI Measurements Live Support Files 1.0, 1.1, and 1.2 Known Issues

Overview

This document contains known issues for NI Measurements Live Support Files. Not every issue known to NI will appear on this list; it is intended to only show the severe and more common issues that can be encountered.

Contacting NI

You can contact us by phone, email, or the discussion forums. Visit the NI Website to contact us. If you are contacting NI in regards to a specific issue, be sure to reference the ID.

Known Issues

The following items are known issues in NI Measurements Live Support Files.

698572Logic Analyzer graph only shows 10 lines on macOS.
698535Logic Analyzer TDMS file export fails.
698001Screen capture does not capture data when using the Bode Analyzer or Current-Voltage Analyzer in Safari.
698303Oscilloscope analog edge trigger switches between rising and falling edge for noisy input signals.
691820Currently Unicode characters are not supported in custom waveform filenames.
698274Failed to connect to NI ELVIS III in Safari 11.0.

 

Use this table to review known issues for NI Measurements Live Support Files.
IDKnown Issue
698572

Return
Logic Analyzer graph only shows 10 lines on macOS.
This is currently a limitation of LabVIEW in macOS.

Workaround: N/A.

Reported Version: 1.0  Resolved Version: N/A  Added: 06/28/2018
698535

Return
Logic Analyzer TDMS file export fails.
The Logic Analyzer allows you to export TDMS files, but currently only CSV files are supported.

Workaround: Export CSV files.

Reported Version: 1.0  Resolved Version: N/A  Added: 06/28/2018
698001

Return
Screen capture does not capture data when using the Bode Analyzer or Current-Voltage Analyzer in Safari.
The first time the screen capture button (camera icon) is pressed in the Bode Analyzer or Current-Voltage Analyzer SFP (Soft Front Panel) in Safari, no data is collected.

Workaround: Press the screen capture button twice to get a valid screenshot.

Reported Version: 1.0  Resolved Version: N/A  Added: 06/28/2018
698303

Return
Oscilloscope analog edge trigger switches between rising and falling edge for noisy input signals.
The analog trigger may activate on a rising edge when set to trigger on a falling edge and vice versa in the Oscilloscope SFP when measuring a noisy signal.

Workaround: N/A.

Reported Version: 1.0  Resolved Version: N/A  Added: 06/28/2018
691820

Return
Currently Unicode characters are not supported in custom waveform filenames.
When attempting to load a custom waveform file in an SFP, the file will fail to load silently.

Workaround: Remove Unicode characters from the filename.

Reported Version: 1.0  Resolved Version: N/A  Added: 06/28/2018
698274

Return
Failed to connect to an NI ELVIS III in Safari 11.0.
Measurements Live is only supported in Safari 11.1 and later.

Workaround: Update Safari to 11.1 or later.

Reported Version: 1.0  Resolved Version: N/A  Added: 06/28/2018

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).