ID Legacy ID Fixed Issue Issue Details
305338 465052 SequenceAdapter.GetSequenceFile() does not enforce Absolute Path If you pass in a relative path to the SequenceAdapter.GetSequenceFile() Method's path parameter, the method accepts this and will execute, often causing errors.
305342 544563 GetGUIDAsString in Modelsupport2.dll does not generate properly formatted GUIDs There is a missing hyphen when the GetGUIDAsString function is used to generate a GUID.
305345 566400 LabVIEW VI absolute path check does not handle PPLs properly At load time, when the LabVIEW Adapter checks VI paths to make sure they are not pointing to two different copies of VIs with the same name, the code does not properly account for packed project libraries (PPLs). If two steps reference a VI with the same name in the same PPL located in different places on disk, the first VI loaded should be used for both VI calls. However, because the function that checks the VI paths does not correctly handle PPLs, an error is generated.
305350 658319 Connector panes that reference large LabVIEW class hierarchies reload the entire hierarchy when selecting a step. If a LabVIEW step references a VI whose connector pane uses data value references or directly uses a large LabVIEW class, the TestStand Sequence Editor reloads the step and all of its dependencies each time the step is selected.
305359 678105 The TestStand Deployment Utility returns the error -19062 when deploying components to a local repository or package installer. If the "NI Certificates Installer" package is not installed on the system, and NI Package Manager cannot locate the package on one of its feeds, when the TestStand Deployment Utility attempts to include NI Certificates package in the distribution, the build returns "error -19062: Could not calculate EULA dependencies".
305362 684110 Clicking on the filter icon for the file column in the log window of the TestStand LabVIEW NXG Conversion Utility throws an exception. When pressing the filter icon button in the TestStand LabVIEW NXG Conversion Utility, the exception "Object reference not set to an instance of an object." occurs.
305365 684203 Unable to load LabVIEW NXG VI under ThisComputer target from project in a path with multibyte characters. If you try to configure a step to load a LabVIEW NXG VI that is placed under the ThisComputer target in the project, and the project is located in a path with multi-byte characters, then you will receive the error "Error thrown in Get VI - LoadEnvoyAsync: Error loading envoy for specified document".
305369 686846 Calling DisplayFlagsDialog() in an application without the UI Controls does not expose the same functionality as an application that contains UI Controls  
305373 691732 Max and Min functions are not NaN aware in expressions  
305375 695916 "Access Denied" Error launching TestStand when Windows user name has Japanese characters When trying to launch TestStand from a user with Japanese characters in the user name, TestStand throws an "Access Denied" error.
305381 709638 Timestamp UTC value will change for a LabVIEW VI step if the sequence file is opened in a different time zone but no edit is done to the step or sequence  
302428 710154 Editing a Sequence Analyzer rule that references a LabVIEW NXG code module crashes the Sequence Analyzer dialog If a rule has been created in the Sequence Analyzer that refers to a LabVIEW NXG code module, then when the "Edit Rule" button is hit it will cause the Sequence Analyzer Available Rules dialog to crash.
306878 711553 Changing base destination of a packed project library in the TestStand Deployment Utility causes the build to fail When building a packed project library with the Deployment Utility, you can select the .lvlibp item in the distributed files tab and change the base destination of the library. If you do so, the VIs in the library are incorrectly configured to have a destination subdirectory which matches the library name. This invalid setting causes the build to fail.
306392 716835 Time Stamp conversion fails intermittently when value passes between TestStand and LabVIEW At random times when Time Stamps are passed back and forth between TestStand and LabVIEW, TestStand sends a Time Stamp string with a resolution of 0.0001 seconds instead of 0.001 seconds. This causes LabVIEW to default to an empty "00:00:00.000 PM MM/DD/YYYY" Time Stamp.
305388 726406 When using the FileOpenMode_Uniquify File Open Mode in the New CSV Output Stream, the non-uniquified name is shown in the report  
305336 728989 TestStand 2019 no longer supports selecting INI format for sequence files TestStand now restricts you to selecting only the XML or binary formats. Configuring TestStand files to save using the INI file format is deprecated, and saving files in INI file format will be deprecated in a future release.

 

The following items are Bug Fixes in TestStand 2019 f1.

 

ID Legacy ID Fixed Issue Issue Details
305876 736115 "Invalid VI Reference" reported during edit-time for a broken VI when the adapter is set to use the LabVIEW Run-time Engine When a broken VI is selected for the module in the TestStand LabVIEW step settings panel, with the adapter configured to RTE, the error message reports "Invalid VI Reference," which does not match what appears in the error log for the VI.
221029 744812 System error occurs when parallel sequence execution uses partial cluster passing Sometimes a system level exception occurs when executing test sequence in parallel that are calling LV code modules which have clusters that contain arrays and are using partial cluster passing feature.

 

The following items are Bug Fixes in TestStand 2019 f2.

 

ID Legacy ID Fixed Issue Issue Details
220503 544646 Error -17313 or -18005 occurs when passing a .NET refnum constant in a cluster from newer versions of LabVIEW into TestStand If a LabVIEW VI with a cluster that contains a .NET refnum is passed into TestStand, then error -17313 or -18005 may occur. An example of this type of refnum would be when you create a constant from a .NET terminal in LabVIEW.
305866 733179 Override settings tab causes hang when running LabVIEW UI from development environment For a LabVIEW code module step, selecting the Override Settings tab in the LabVIEW module settings dialog causes a hang when running the LabVIEW User Interface from the LabVIEW Development Environment

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.