Critical Security Update

To help protect your systems, customers using NI driver software 2026 Q2 or earlier should visit ni.com/ni-pal-update and follow the recommended actions.

Vehicle Communication Toolkit 2026 Q4 Known Issues

Overview

This document contains the Vehicle Communication Toolkit known issues that were discovered before and since the release of Vehicle Communication Toolkit 2026 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.

Bug Number

Legacy ID

Description

Details

4086160

VCOM Config XML - SecOC Configuration

When configuring SecOC using the WebUI, the SecOCKey parameter is written incorrectly to the VCOM configuration XML file.

As a result, the configured SecOC key is not applied and the default key is used instead. No error or warning is reported. The issue may therefore only become apparent when the generated SecOC payload does not match the expected payload on the bus.

The parameter should be saved as:
<SecOCKey>

However, it is currently saved as:
<SOKKey>

Current XML:
<SecOC>
    <OEM>****</OEM>
    <Config>
        <SOKKey>
            <DataID>****</DataID>
            <Key>****</Key>
        </SOKKey>
    </Config>
</SecOC>

Expected XML:
<SecOC>
    <OEM>****</OEM>
    <Config>
        <SecOCKey>
            <DataID>****</DataID>
            <Key>****</Key>
        </SecOCKey>
    </Config>
</SecOC>

Workaround:

After saving the configuration, open the XML file in a text editor and replace all SOKKey tags with SecOCKey tags.

Reported Version:

Vehicle Communication Toolkit: 2025 Q1

Resolved Version:

N/A

Added:

N/A

4086105

TreeView Error When Opening Older NI-VCOM Projects in a Newer Version

When a VeriStand project created with an earlier version (2025 Q3) of NI-VCOM is opened in a newer version (2026 Q2), the TreeView displays the following error:

Failed to load data: One or more errors occurred.

This issue occurs because the internal format of the SignalList.dat file changed between NI-VCOM versions. As a result, the newer version cannot correctly interpret a file generated by an earlier version.

Workaround:

Delete the existing SignalList.dat file located in the project’s VCOMConfiguration_Controller folder. Then run Set VCOM Configuration without making any other changes. NI-VCOM automatically regenerates the SignalList.dat file in the format required by the currently installed NI-VCOM version. After regeneration, the TreeView can be loaded normally

Reported Version:

Vehicle Communication Toolkit: 2026 Q2

Resolved Version:

N/A

Added:

N/A

4089717

Bus Monitor does not support array signals

The VCOM Bus Monitor does not support displaying array data types defined in the database. For example, if an Automotive Ethernet PDU contains an array data type, the VCOM Bus Monitor does not display the value as an array structure. Instead, the PDU value is displayed as a single (scalar) value.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

Vehicle Communication Toolkit: 2026 Q2

Resolved Version:

N/A

Added:

N/A

4086102

CAN FD Frame With Length Greater Than 8 Bytes Shows Invalid Length Error

In VCOM 2026 Q2, after configuring a custom bitrate, any CAN FD frame with a payload length greater than 8 bytes fails to be loaded by NI VCOM System Explorer and reports an error. The issue is reproducible with the built-in NI-VCOM_CAN-FD_Example Demo.

Workaround:

Initially configure the VCOM configuration page without specifying the custom bitrate and data bitrate values. Then generate the signal tree as part of the offline processing step. The generated signal tree is independent of the custom bitrate and data bitrate settings. These values configure the CAN transceiver and do not affect signal-tree generation. Before starting online processing (deployment), manually add the required custom bitrate and data bitrate tags to the generated XML configuration file, as shown below. Example: <Port>     <Name>CAN_Receiver</Name>     <Class>RC_CCANPort</Class>     <Config>         <HWPort>CAN2</HWPort>         <BitRate>500000</BitRate>         <DataBitRate>2000000</DataBitRate>         <CustomBitRate>32A0041E07</CustomBitRate>         <CustomDataBitRate>800F00A0032E30</CustomDataBitRate>     </Config> </Port>

Reported Version:

Vehicle Communication Toolkit: 2026 Q2

Resolved Version:

N/A

Added:

N/A

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).