Critical Security Update
To help protect your systems, customers using NI driver software 2026 Q2 or earlier should visit ni.com/ni-pal-update and follow the recommended actions.
This document contains the Vehicle Communication (VCOM) Toolkit known issues that were discovered before and since the release of Vehicle Communication Toolkit 2026 Q2. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 2870604 |
[Known Issues Version 2025 Q3] Importing a Config from ZIP returns an Error 1092When you import a previous exported config from the system explorer, you get an error 1092. ![]() To reproduce, use the shipping example, create a config and import all the channels. Then export that config. Delete the config and try to import your new zip file. Include relevant system information, steps to reproduce, and any workarounds.
Workaround: There is currently no known workaround for this issue. |
Reported Version: Vehicle Communication Toolkit: 2024 Q4 Resolved Version: N/A Added: N/A |
|
| 3219048 |
[WebUI] XNET Custom Interface support change in VCOM 2025Q3 requestThe customer tried to use the DLL based XNET custom interface usage in VCOM (25Q3) ![]() Gets the following error:
ImpactCustomer is not able to use the feature
Steps to reproduce
Workaround:
For example, from this:
<Device>
<Name>CAN_NI-XNET1</Name>
<Class>RC_CNIXnetDevice</Class>
<Config>
<clock_src>SysClock</clock_src>
<Port>
<Name>Demo_ECU</Name>
<Class>RC_CCANPort</Class>
<Config>
<HWPort>CAN2</HWPort>
<BitRate>500000</BitRate>
<DataBitRate>2000000</DataBitRate>
<AckBit>true</AckBit>
<NWDescriptor>VCOM_Example_CAN-FD_Autosar.arxml</NWDescriptor>
<EnableBusTermination>true</EnableBusTermination>
<NIXNETCustomInterface>{path}</NIXNETCustomInterface>
<Triggering>None</Triggering>
<ConfigureNM>false</ConfigureNM>
</Config>
</Port>
</Config>
</Device>
To this:
<Device>
<Name>CAN_NI-XNET1</Name>
<Class>RC_CNIXnetDevice</Class>
<Config>
<clock_src>SysClock</clock_src>
<Port>
<Name>Demo_ECU</Name>
<Class>RC_CCANPort</Class>
<Config>
<HWPort>CAN2</HWPort>
<BitRate>500000</BitRate>
<DataBitRate>2000000</DataBitRate>
<AckBit>true</AckBit>
<NWDescriptor>VCOM_Example_CAN-FD_Autosar.arxml</NWDescriptor>
<EnableBusTermination>true</EnableBusTermination>
<PSPRFMPath>{path}</PSPRFMPath>
<PSPRFMConfig>{config}</PSPRFMConfig>
<Triggering>None</Triggering>
<ConfigureNM>false</ConfigureNM>
</Config>
</Port>
</Config>
</Device>
|
Reported Version: Vehicle Communication Toolkit: 2025 Q3 Resolved Version: N/A Added: N/A |
|
| 3100992 |
LabVIEW application Crash after VI execution where using VCOM LabVIEW API VI’s not following recommended flow.A LabVIEW application may crash unexpectedly (application termination) if the VCOM LabVIEW API VIs are not used according to the recommended execution flow. One example of incorrect API usage is demonstrated using the shipping example: Plain Text
In this scenario, the issue is introduced by removing the Observed Behavior
VCOM example:
VCOM Example (modified): ![]()
The main cause of that is by not closing VCOM Session it keeps some resources busy and causes unexpected behavior of the application (in this case crush).
Reported In (Version) 2026 Q2 Workaround: To avoid this kind of issues always use the recommended workflow of the VCOM described in documentation and shown in examples.
|
Reported Version: Vehicle Communication Toolkit: 2025 Q1 Resolved Version: N/A Added: N/A |
|
| 3780069 |
VCOM Config XML Ethernet structure changeDescriptionEthernet structure change (XNET Automotive Ethernet)
Required XML update
Hardware Port parameter name change
Required XML update
Custom (CRC) interface structure change
Workaround: To migrate existing configurations and keep compatibility with the new structure, update the XML as follows:
|
Reported Version: Vehicle Communication Toolkit: 2025 Q3 Resolved Version: N/A Added: N/A |
|
| 3781533 |
Importing Configuration Results in VCOM Decimation Value of -1
When importing a configuration, the Decimation value may be set to -1 if the configured target rate is not valid for the selected Custom Device rate. This issue occurs when a valid integer decimation factor cannot be calculated between the Custom Device rate and the target rate. As a result:
Clicking the warning icon opens the System Explorer Errors window, which displays an error message describing the invalid rate configuration.
Workaround: Adjust one of the following: the Custom Device Rate or the Target Rate. |
Reported Version: N/A Resolved Version: N/A Added: N/A |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.
Explore Support Content and Product Documentation
Ask the NI Community
Request Support from an Engineer
A valid service agreement may be required, and support options vary by country