This document contains the Vehicle Communication (VCOM) Toolkit known issues that were discovered before and since the release of Vehicle Communication Toolkit 2026 Q2. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.

Bug Number

Legacy ID

Description

Details

2870604

[Known Issues Version 2025 Q3] Importing a Config from ZIP returns an Error 1092

When you import a previous exported config from the system explorer, you get an error 1092.

Image

To reproduce, use the shipping example, create a config and import all the channels. Then export that config.

Delete the config and try to import your new zip file.
Include relevant system information, steps to reproduce, and any workarounds.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

Vehicle Communication Toolkit: 2024 Q4

Resolved Version:

N/A

Added:

N/A

3219048

[WebUI] XNET Custom Interface support change in VCOM 2025Q3 request

The customer tried to use the DLL based XNET custom interface usage in VCOM (25Q3)

Image
Gets the following error:

image

Impact

Customer is not able to use the feature

Steps to reproduce

  1. Open configuration tool (WebUI)
  2. For "CAN" function module navigate to the "Hardware Port"
  3. Fill the "NIXNET Custom Interface" optional field.
  4. Save the configuration and run the simulation using saved file.

Workaround:

  1. 1. Rename the two main function calls in his code and recompile it
    • GetPSPRFMConfig (former GetNIXNETCustomConfig)
    • GetPSPRFMInterfaceInfo (former GetNIXNETCustomInterfaceInfo)
  2. Make change VCOMConfig.xml file manually:
    • Rename “NIXNETCustomInterface” to “PSPRFMPath” - to define the path to .dll or .so file that implements custom frame manipulation
    • Add “PSPRFMConfig” - an optional configuration string for PSPRFM interface
For example, from this:

<Device>
    <Name>CAN_NI-XNET1</Name>
    <Class>RC_CNIXnetDevice</Class>
    <Config>
        <clock_src>SysClock</clock_src>
        <Port>
            <Name>Demo_ECU</Name>
            <Class>RC_CCANPort</Class>
            <Config>
                <HWPort>CAN2</HWPort>
                <BitRate>500000</BitRate>
                <DataBitRate>2000000</DataBitRate>
                <AckBit>true</AckBit>
                <NWDescriptor>VCOM_Example_CAN-FD_Autosar.arxml</NWDescriptor>
                <EnableBusTermination>true</EnableBusTermination>
                <NIXNETCustomInterface>{path}</NIXNETCustomInterface>
                <Triggering>None</Triggering>
                <ConfigureNM>false</ConfigureNM>
            </Config>
        </Port>
    </Config>
</Device>
To this:
<Device>
    <Name>CAN_NI-XNET1</Name>
    <Class>RC_CNIXnetDevice</Class>
    <Config>
        <clock_src>SysClock</clock_src>
        <Port>
            <Name>Demo_ECU</Name>
            <Class>RC_CCANPort</Class>
            <Config>
                <HWPort>CAN2</HWPort>
                <BitRate>500000</BitRate>
                <DataBitRate>2000000</DataBitRate>
                <AckBit>true</AckBit>
                <NWDescriptor>VCOM_Example_CAN-FD_Autosar.arxml</NWDescriptor>
                <EnableBusTermination>true</EnableBusTermination>
                <PSPRFMPath>{path}</PSPRFMPath>
                <PSPRFMConfig>{config}</PSPRFMConfig>
                <Triggering>None</Triggering>
                <ConfigureNM>false</ConfigureNM>
            </Config>
        </Port>
    </Config>
</Device>

Reported Version:

Vehicle Communication Toolkit: 2025 Q3

Resolved Version:

N/A

Added:

N/A

3100992

LabVIEW application Crash after VI execution where using VCOM LabVIEW API VI’s not following recommended flow.

A LabVIEW application may crash unexpectedly (application termination) if the VCOM LabVIEW API VIs are not used according to the recommended execution flow.

One example of incorrect API usage is demonstrated using the shipping example:

Plain Text
C:\Program Files\National Instruments\LabVIEW {year}\examples\
Vehicle Communication Toolkit\VCOM Base Examples\
VCOM Base - CAN Restbus Simulation with Demo ECU - DBC Network Descriptor.vi

In this scenario, the issue is introduced by removing the Close Session.vi from the example.

Observed Behavior

  • The VI executes and operates as expected during runtime.
  • When the application execution is stopped using the “STOP” button, the LabVIEW application crashes and closes unexpectedly.

 

VCOM example:

 Image

 

VCOM Example (modified):

Image

 

The main cause of that is by not closing VCOM Session it keeps some resources busy and causes unexpected behavior of the application (in this case crush).

 

Reported In (Version)

2026 Q2


Workaround:

To avoid this kind of issues always use the recommended workflow of the VCOM described in documentation and shown in examples.

Reported Version:

Vehicle Communication Toolkit: 2025 Q1

Resolved Version:

N/A

Added:

N/A

3780069

VCOM Config XML Ethernet structure change

Description

Ethernet structure change (XNET Automotive Ethernet)
  • Class update
  • XNET Automotive Ethernet has been moved from the device class RC_CEthernetDevice (which previously required the special XML key UseNiIPStack) to RC_CNIXnetDevice.
  • As a result, UseNiIPStack is now obsolete and should no longer be used.
Required XML update
  • Any XML configuration that uses RC_CEthernetDevice must be updated to RC_CNIXnetDevice.
Hardware Port parameter name change
  • The subordinate configuration parameter under RC_CEthernetPort was renamed from DeviceName to HWPort to align with other XNET port definitions.
Required XML update
  • Any XML configuration that contains the tag … must be updated to ....
Custom (CRC) interface structure change
  • The execution of the custom DLL/SO has been moved into the PSPRFM module.
  • The PSPRFM module is now configured using specific XML parameters.
  • PSPRFMPath (formerly NIXNETCustomInterface): path to the .dll (Windows) or .so (Linux) implementing the custom frame manipulation logic.
  • PSPRFMConfig: optional configuration string for the PSPRFM interface.

Workaround:

To migrate existing configurations and keep compatibility with the new structure, update the XML as follows:

  1. Update the Ethernet device class
    Replace all occurrences of RC_CEthernetDevice with RC_CNIXnetDevice

  2. Remove the obsolete IP stack key
    Remove the XML key UseNiIPStack

  3. Rename the Ethernet port parameter
    Under RC_CEthernetPort, rename the tag DeviceName to HWPort

  4. Migrate the custom interface configuration to PSPRFM
    Replace the former parameter NIXNETCustomInterface with PSPRFMPath
    Optionally add PSPRFMConfig if additional configuration is required by the PSPRFM implementation.

Reported Version:

Vehicle Communication Toolkit: 2025 Q3

Resolved Version:

N/A

Added:

N/A

3781533

Importing Configuration Results in VCOM Decimation Value of -1

When importing a configuration, the Decimation value may be set to -1 if the configured target rate is not valid for the selected Custom Device rate.

This issue occurs when a valid integer decimation factor cannot be calculated between the Custom Device rate and the target rate. As a result:

  • The Decimation field is set to -1
  • System Explorer reports an error
  • A warning icon appears in the toolbar indicating a configuration issue

Clicking the warning icon opens the System Explorer Errors window, which displays an error message describing the invalid rate configuration.

image

Workaround:

Adjust one of the following: the Custom Device Rate or the Target Rate.

Reported Version:

N/A

Resolved Version:

N/A

Added:

N/A

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).