This document contains the RFIC Test Software known issues that were discovered before and since the release of RFIC Test Software 2026 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 3995878 |
Envelope Tracking (ET) Fails with SDC Control During NI-TClk ConfigurationWhen running Envelope Tracking (ET) with SDC control, the measurement may fail during NI-TClk Homogeneous Triggering configuration. This issue occurs because ET with SDC control requires synchronization between the Digital, VST, and Baseband instruments using NI-TClk. During NI-TClk configuration, RFIC obtains the niDigital session from the SDC layer. In certain software configurations, the niDigital session provided by SDC is not compatible with the NI-TClk synchronization requirements used by RFIC, resulting in a NI-TClk configuration failure and preventing ET measurements from running successfully. Affected Configuration Envelope Tracking (ET) SDC Control Workaround: Known Limitation
There is currently no workaround available for this issue. Supported Configuration: Use the RFIC 2025 Q4 software release with the corresponding supported SDC and NI Digital driver versions documented for that release.
|
Reported Version: RFIC Test Software: 2026 Q4 Resolved Version: N/A Added: N/A |
|
| 2952808 |
'LO Session Reservation Error' when Using Multiple RFIC Features TogetherWhen multiple RFIC features are enabled simultaneously, the RFIC Soft Front Panel (SFP) may return the following error :
This issue occurs when the following features are enabled together:
Workaround: Disable LO sharing.
|
Reported Version: RFIC Test Software: 24.0 Resolved Version: N/A Added: N/A |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.