This document contains the NI-SmartNIC known issues that were discovered before and since the release of NI-SmartNIC 2026 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 3162256 |
Compiling FPGA bitfiles using AMD Vivado scripts will fail with "DRC INBB-3" errorAfter generating intermediate files, when compiling an FPGA bitfile for PXIe-8290 using AMD Vivado scripts the compile fails with a "DRC INBB-3 black box" error. Workaround: This issue can occur because of limited file permissions for the user executing the Vivado compile script which can prevent being able to write output files into their default directory. This can be avoided by changing the output directory of the generated scripts. - After generating intermediate files, go to where they were generated. - Under ".../src/gen/..." modify both AuroraFramingGtm.bd and AuroraFramingGtyp.bd, - Where is says "gen_directory": "../../../../VivadoProject" remove two "../" from the relative path. - The result should look something like "gen_directory": "../../VivadoProject" - You should now be able to run a Vivado build without error. |
Reported Version: NI-SmartNIC: 2025 Q3 Resolved Version: N/A Added: Jul 21, 2025 |
|
| 3353586 |
PXIe-8290 will power down when a thermal or power limit is reached after the user session is stoppedIf the PXIe-8290 is used in such a way that it exceeds the power or thermal rating, it will stop the user's session to reduce power usage. If that is not sufficient to maintain safe power usage and temperatures, the PXIe-8290 will power down, likely causing the PXI controller to crash with a BSoD. Workaround: To avoid this issue, monitor that the temperature remains below 98 degrees Celsius in NI Hardware Configuration Utility, and verify that the Module Cooling property reports it's state to be Normal.
|
Reported Version: NI-SmartNIC: 2025 Q4 Resolved Version: N/A Added: Oct 20, 2025 |
|
| 3880782 |
Opening an Instruction Framework Session sometimes fails for PXIe-8290 ApplicationsThe first instruction framework access after a bitfile download on PXIe-8290 will hang, as will subsequent accesses to that same instance.
Workaround: Explicitly start all of the FIFOs in the design, even if not all are needed, before attempting to use any of them.
|
Reported Version: NI-SmartNIC: 2026 Q2 Resolved Version: N/A Added: Jun 10, 2026 |
|
| 3834930 |
PXIe-8290 devices might cause crash during loadPXIe-8290 devices might cause crash during load.
Workaround: There is currently no known workaround for this issue. |
Reported Version: NI-SmartNIC: 2026 Q1 Resolved Version: N/A Added: Jun 10, 2026 |
|
| 4088684 |
CLIPs assigned to PXIe-8290 targets are unassigned after saving and reopening .lvproj fileUsing LabVIEW 2026, saving and reopening a project removes the CLIP assignment from a PXIe-8290 target. Bitfiles produced in this state will return error -61018 during download.
Workaround: Move the CLIP into a folder named "Socketed CLIPs" alongside the .lvproj file. Reassign the CLIP and save the project.
|
Reported Version: NI-SmartNIC: 2026 Q1 | NI-SmartNIC: 2026 Q2 | NI-SmartNIC: 2026 Q3 | NI-SmartNIC: 2026 Q4 Resolved Version: N/A Added: Oct 6, 2026 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.