Critical Security Update

To help protect your systems, customers using NI driver software 2026 Q2 or earlier should visit ni.com/ni-pal-update and follow the recommended actions.

NI-Industrial Communications for EtherCAT 2026 Q4 Known Issues

Overview

This document contains the NI-Industrial Communications for EtherCAT known issues that were discovered before and since the release of NI-Industrial Communications for EtherCAT 2026 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.

Bug Number

Legacy ID

Description

Details

3872156

Modules cannot be loaded out of sequential slot order

When loading modules to an EtherCAT device, each module is automatically placed into the next available slot. There is no way to add a module to a specific slot out of sequential order, so configurations that require an empty slot between populated slots cannot be created directly.

Workaround:

Load all slots in sequential order, even if slots are empty. (Slot 1: Module X, Slot 2: <empty>, Slot 3: Module Y, etc.)

Reported Version:

NI-Industrial Communications for EtherCAT 2023 Q3

Resolved Version:

N/A

Added:

Oct 12, 2026

3872172

ESI validation warning not shown if modules are not present

When a top-level ESI is imported with modules that are not present, LabVIEW reports no warnings.  The modules are configured, but unusable.

Workaround:

Manually remove the configured modules in LabVIEW, or install the missing modules in the subdevice.

Reported Version:

NI-Industrial Communications for EtherCAT 2026 Q3

Resolved Version:

N/A

Added:

Oct 12, 2026

4105711

NI MAX cannot save Ethernet adapter's mode as EtherCAT for a Linux RT target

NI MAX cannot save the secondary Ethernet adapter’s mode as EtherCAT on a PXIe Linux RT target. Saving the adapter’s mode as Disabled or TCP/IP succeeds.

Error (NI MAX):
There was a problem saving the settings to the target. Make sure your hardware is powered on and that it is connected to the network.

Workaround:

Install NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1; keep the default install option for NI Measurement & Automation Explorer.  Set the secondary Ethernet adapter's mode.

Reported Version:

NI-Industrial Communications for EtherCAT 2026 Q4

Resolved Version:

NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1

Added:

Oct 27, 2026

4125977

EtherCAT Master deployment fails with error 0xFFFEFC65

When an EtherCAT device is added to a LabVIEW project from an ESI file that defines inactive PDOs, LabVIEW adds the inactive PDOs as project I/O. Deploying the EtherCAT Master then fails with error 0xFFFEFC65.

Error
LabVIEW: (Hex 0xFFFEFC65) The configuration for the I/O channel you accessed is not internally consistent due to a pending configuration change. Try to access the channel again after the configuration operation is complete.

Workaround:

Install NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1, then redeploy.

Reported Version:

NI-Industrial Communications for EtherCAT 2026 Q4

Resolved Version:

NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1

Added:

Oct 27, 2026

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a worldwide basis.

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).