This document contains the NI-Industrial Communications for EtherCAT known issues that were discovered before and since the release of NI-Industrial Communications for EtherCAT 2026 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 3872156 |
Modules cannot be loaded out of sequential slot orderWhen loading modules to an EtherCAT device, each module is automatically placed into the next available slot. There is no way to add a module to a specific slot out of sequential order, so configurations that require an empty slot between populated slots cannot be created directly.
Workaround: Load all slots in sequential order, even if slots are empty. (Slot 1: Module X, Slot 2: <empty>, Slot 3: Module Y, etc.)
|
Reported Version: NI-Industrial Communications for EtherCAT 2023 Q3 Resolved Version: N/A Added: Oct 12, 2026 |
|
| 3872172 |
ESI validation warning not shown if modules are not presentWhen a top-level ESI is imported with modules that are not present, LabVIEW reports no warnings. The modules are configured, but unusable. Workaround: Manually remove the configured modules in LabVIEW, or install the missing modules in the subdevice.
|
Reported Version: NI-Industrial Communications for EtherCAT 2026 Q3 Resolved Version: N/A Added: Oct 12, 2026 |
|
| 4105711 |
NI MAX cannot save Ethernet adapter's mode as EtherCAT for a Linux RT targetNI MAX cannot save the secondary Ethernet adapter’s mode as EtherCAT on a PXIe Linux RT target. Saving the adapter’s mode as Disabled or TCP/IP succeeds. Error (NI MAX): Workaround: Install NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1; keep the default install option for NI Measurement & Automation Explorer. Set the secondary Ethernet adapter's mode.
|
Reported Version: NI-Industrial Communications for EtherCAT 2026 Q4 Resolved Version: NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1 Added: Oct 27, 2026 |
|
| 4125977 |
EtherCAT Master deployment fails with error 0xFFFEFC65When an EtherCAT device is added to a LabVIEW project from an ESI file that defines inactive PDOs, LabVIEW adds the inactive PDOs as project I/O. Deploying the EtherCAT Master then fails with error 0xFFFEFC65. Error LabVIEW: (Hex 0xFFFEFC65) The configuration for the I/O channel you accessed is not internally consistent due to a pending configuration change. Try to access the channel again after the configuration operation is complete. Workaround: Install NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1, then redeploy. |
Reported Version: NI-Industrial Communications for EtherCAT 2026 Q4 Resolved Version: NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1 Added: Oct 27, 2026 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.
Explore Support Content and Product Documentation
Ask the NI Community
Request Support from an Engineer
A valid service agreement may be required, and support options vary by country
The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a worldwide basis.