The following items are notable issues fixed between the release of NI-Industrial Communications for EtherCAT 2026 Q3and NI-Industrial Communications for EtherCAT 2026 Q4, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI-Industrial Communications for EtherCAT.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 3929189 |
EtherCAT device signals fail to appear in LabVIEW when any signal name contains an special character (/, &, <, >, quotes)When an ESI file contains a signal whose name includes special characters (/, &, <, >, quotes), none of the device signals enumerate in LabVIEW. All signals under that device, including the one containing special characters, do not appear in the LabVIEW EtherCAT Master's device list.
Workaround: Edit the ESI file and remove the special characters from the signal name.
|
Reported Version: NI-Industrial Communications for EtherCAT 2026 Q2 Resolved Version: NI-Industrial Communications for EtherCAT 2026 Q4 Added: Oct 12, 2026 |
|
| 3961222 |
EtherCAT driver no longer shows SDO status in the Online Slave Device State pageThe "Online Slave Device State" >> "EtherCATParameters" page does not show the SDO parameters set for an online subdevice.
Workaround: Upgrade to NI-Industrial Communications for EtherCAT 2026 Q4.
|
Reported Version: NI-Industrial Communications for EtherCAT 2023 Q3 Resolved Version: NI-Industrial Communications for EtherCAT 2026 Q4 Added: Oct 12, 2026 |
|
| 3970539 |
ESI file fails to importImporting certain EtherCAT device description (ESI) files fails, preventing device setup. Error Message: NI-Industrial Communications for EtherCAT The software cannot import the device profile. Refer to the NI-Industrial Communications for EtherCAT Help for more information about the causes of the failure.
Workaround: Press Import twice, or import within a larger group of ESI files. Fixed in NI-Industrial Communications for EtherCAT 2026 Q4.
|
Reported Version: NI-Industrial Communications for EtherCAT 2026 Q3 Resolved Version: NI-Industrial Communications for EtherCAT 2026 Q4 Added: Oct 12, 2026 |
|
| 4105711 |
NI MAX cannot save Ethernet adapter's mode as EtherCAT for a Linux RT targetNI MAX cannot save the secondary Ethernet adapter’s mode as EtherCAT on a PXIe Linux RT target. Saving the adapter’s mode as Disabled or TCP/IP succeeds. Error (NI MAX): Workaround: Install NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1; keep the default install option for NI Measurement & Automation Explorer. Set the secondary Ethernet adapter's mode.
|
Reported Version: NI-Industrial Communications for EtherCAT 2026 Q4 Resolved Version: NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1 Added: Oct 27, 2026 |
|
| 4125977 |
EtherCAT Master deployment fails with error 0xFFFEFC65When an EtherCAT device is added to a LabVIEW project from an ESI file that defines inactive PDOs, LabVIEW adds the inactive PDOs as project I/O. Deploying the EtherCAT Master then fails with error 0xFFFEFC65. Error LabVIEW: (Hex 0xFFFEFC65) The configuration for the I/O channel you accessed is not internally consistent due to a pending configuration change. Try to access the channel again after the configuration operation is complete. Workaround: Install NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1, then redeploy. |
Reported Version: NI-Industrial Communications for EtherCAT 2026 Q4 Resolved Version: NI-Industrial Communications for EtherCAT 2026 Q4 Patch 1 Added: Oct 27, 2026 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.