Critical Security Update
To help protect your systems, customers using NI driver software 2026 Q2 or earlier should visit ni.com/ni-pal-update and follow the recommended actions.
This document contains the LabVIEW Real-Time Module known issues that were discovered before and since the release of LabVIEW 2026 Q1 Real-Time Module. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 3760250 |
RT Get CPU Loads.vi Returns the Same Value for All CPUs Regardless of CPU PoolThe API Reference documentation for RT Get CPU Loads.vi states: "LabVIEW 2026Q1 and later: On Linux RT targets, the per-CPU load of Timed Structures may be averaged between all CPUs present in the Timed Structures pool." However, the VI is disregarding the CPU pool assignment and returning the same value for all CPUs.
Workaround: Fixed in NI Linux RT feed: https://download.ni.com/#ni-linux-rt/feeds/2026Q1/ni-lv2026/
|
Reported Version: LabVIEW Real-Time Module 2026 Q1 Resolved Version: N/A Added: Apr 16, 2026 |
|
| 3752546 |
Cannot Connect to Target When Using Localized LabVIEW Real-Time (Japanese or Simplified Chinese)When using a localized version of LabVIEW Real-Time (i.e., Japanese or Simplified Chinese), the following error is shown when attempting to connect to the RT target even when the locale is configured appropriately via NI MAX: "Access denied : Language set in the target is not compatible with LabVIEW language. Check the languages in the target and host matched and target locale is configured in MAX." Workaround: Fixed in NI Linux RT feed: https://download.ni.com/#ni-linux-rt/feeds/2026Q1/ni-lv2026/
|
Reported Version: LabVIEW Real-Time Module 2026 Q1 Resolved Version: N/A Added: Apr 16, 2026 |
|
| 3901764 |
Unable to Add Targets to Project When Using 64-bit Japanese LabVIEW with 64-bit English Real-Time and FPGA ModulesWorkaround: Use 32-bit LabVIEW Japanese if you require RT and FPGA functionality.
|
Reported Version: LabVIEW FPGA Module 2026 Q1 | LabVIEW Real-Time Module 2026 Q1 | LabVIEW 2026 Q1 | LabVIEW 2026 Q3 Resolved Version: N/A Added: Jul 24, 2026 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.