VeriStand 2025 Q3 Bug Fixes

Overview

The following items are notable issues fixed between the release of VeriStand 2025 Q2 and VeriStand 2025 Q3, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of VeriStand.

Bug Number

Legacy ID

Description

Details

3031477

Unable to configure a low-pass filter for AI channels of PXIe-43xx cards in VeriStand System Explorer.

Few DAQ modules are not configurable in Veristand System explorer when DAQ device is added to system definition, even though they have a user-configurable lowpass filter for their analog input channels

Workaround:

There is currently no known workaround for this issue.

Reported Version:

VeriStand 2024 Q3 | VeriStand 2024 Q4 | VeriStand 2025 Q1

Resolved Version:

VeriStand 2025 Q3

Added:

Jul 15, 2025

3136181

LabVIEW model generation for VeriStand fails to build when using default Destination path

Building a LabVIEW model for VeriStand fails with misleading error 1430 when using the default settings for destination path.

Workaround:

Initiate build again by manually selecting the destination path

Reported Version:

LabVIEW 2025 Q3 | VeriStand 2025 Q3

Resolved Version:

VeriStand 2025 Q3

Added:

N/A

2913362

VeriStand Screen fails to update controls when System Definition is deployed externally

When a System Definition is deployed via veristand-server or a custom application using the VeriStand API, the VeriStand user interface does not update screen controls and indicators upon launch.

Workaround:

Go to Tools -> Manage Targets. Press disconnect and then connect.

Reported Version:

VeriStand 2024 Q3

Resolved Version:

VeriStand 2025 Q3

Added:

N/A

3073118

Deployment fails when loading more than 26 .vsmodel files in VeriStand

VeriStand encounters a deployment error when more than 26 .vsmodel files are loaded into a System Definition

Workaround:

There is currently no known workaround for this issue.

Reported Version:

VeriStand 2024 Q4

Resolved Version:

VeriStand 2025 Q3

Added:

N/A

Additional Patch Information

Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.

These patches currently do not have any special instructions.

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).