The following items are notable issues fixed between the release of NI-SmartNIC 2025 Q3 and NI-SmartNIC 2025 Q4, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI-SmartNIC.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 3190657 |
PXIe-8290 example project hangs in executionWhen running the PXIe-8290 Aurora example, the top level host VI hangs when waiting for the PLL lock.
Workaround: Move the IO Node Write of xFF to GtPowerGoodIn to occur before the loop that waits for aGTPllLocked.
|
Reported Version: NI-SmartNIC: 2025 Q3 Resolved Version: NI-SmartNIC: 2025 Q4 Added: Jul 21, 2025 |
|
| 2965170 |
PXIe-8290 trigger and PCIe lines do not associate with the same PXIe slot numberThe PXIe-8290 is a 2-slot module. The trigger line will report a slot that is different from the slot reported by the PCIe lines and by geographic address.
Workaround: Upgrade to NI-SmartNIC 2025 Q4 or later
|
Reported Version: NI-SmartNIC: 2025 Q3 Resolved Version: NI-SmartNIC: 2025 Q4 Added: N/A |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.