NI CompactRIO 2025 Q3 Bug Fixes

Overview

The following items are notable issues fixed between the release of NI CompactRIO 2025 Q2 and NI CompactRIO 2025 Q3, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI CompactRIO 2025 Q3.

Bug Number

Legacy ID

Description

Details

1516233

Adding a CLIP on an sbRIO on a Windows machine with some locales might fail

Adding a CLIP on an sbRIO on a Windows machine with any locale that uses a ',' as the decimal character fails with the following error:

"Declaration is not valid.
Warning Info: This CLIP may have been generated for a different version of LabVIEW than you are currently running. Therefore, this CLIP might fail to compile or might not function correctly. To fix this issue, regenerate the CLIP in the latest version of LabVIEW."

Workaround:

Either of the following can be used as a workaround:
  • Change the decimal symbol in the Windows locale from ',' to '.'.
  • Set useLocaleDecimalPoint=False in LabVIEW.ini.

Reported Version:

NI CompactRIO: 20.0 | NI CompactRIO: 20.5 | NI CompactRIO: 21.0

Resolved Version:

NI CompactRIO: 2025 Q3

Added:

Jul 24, 2021

1596481

Installing R-Series before CompactRIO Could Lead To CompactRIO FPGA Targets Creation Failure

MXIe-RIO targets cannot be created in a LabVIEW project if CompactRIO is installed before R-Series.

Workaround:

Install CompactRIO before installing R-Series

Reported Version:

NI CompactRIO: 21.0 | NI-RIO: 21.0

Resolved Version:

NI CompactRIO: 2025 Q3

Added:

Aug 8, 2022

2483344, 2491964

Launching the sbRIO CLIP generator on LabVIEW 2023 Q1 and later will not work

When trying to open the sbRIO CLIP generator in LabVIEW 2023 Q1 and later 64-bit by right-clicking on the FPGA target of a compatible sbRIO controller and selecting the "Launch sbRIO CLIP Generator" option, the sbRIO CLIP Generator does not initialize and no error message is displayed.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

LabVIEW: 2023 Q1 | NI CompactRIO: 2023 Q1

Resolved Version:

NI CompactRIO: 2025 Q3

Added:

Oct 12, 2023

Additional Patch Information

Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.

These patches currently do not have any special instructions.

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).