The following items are notable issues fixed between the release of InstrumentStudio 2025 Q3 and InstrumentStudio 2025 Q4, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of InstrumentStudio.
|
Bug Number |
Legacy ID |
Description |
Details |
|---|---|---|---|
| 3174709 |
System.ValueTuple Run-Time Error When Running Measurement Plug-in Step From TestStand 2025 Q2 and TestStand 2025 Q3Running a Measurement step in TestStand 2025 Q2 (24.9) or TestStand 2025 Q3 (25.5) may report an error with the Run-Time Error dialog where the description contains a message similar to "Method not found: `System.Threading.Tasks.Task`<System.ValueTuple`..." This problem can be seen in these versions of TestStand regardless of which version of InstrumentStudio is installed as long as that InstrumentStudio supports that version of TestStand. This issue will be resolved in InstrumentStudio 2025 Q4. Steps to Reproduce:
Workaround: Unload all modules or restart TestStand. Then, run the sequence before performing an action that would attempt to configure a Measurement step.
|
Reported Version: InstrumentStudio 2025 Q1 | InstrumentStudio 2025 Q2 | InstrumentStudio 2025 Q3 | TestStand 2025 Q2 | TestStand 2025 Q3 Resolved Version: InstrumentStudio 2025 Q4 Added: Jul 11, 2025 |
|
| 2756123, 3214362 |
In TestStand 2025 Q3, using Measurement Plug-in and FlexLogger steps together fail if one is version 2025 Q3 and the other a newer versionIn TestStand 2025 Q3 (25.5), using a Measurement Plug-in step and a FlexLogger step will lead to a Run-Time Error if either InstrumentStudio or FlexLogger is version 2025 Q3 (25.5) while the other is a newer version. It should be okay for InstrumentStudio/FlexLogger mismatches as long as both versions are greater than or equal to version 2025 Q4 (25.8). The Run-Time Error will include a message saying it could not load GrpcChannelFactory or an exception occurred in MeasurementStepExecution. Workaround: Install the same version of InstrumentStudio and FlexLogger. Typically, this should mean upgrading to the newer version.
|
Reported Version: FlexLogger 2025 Q3 | FlexLogger 2025 Q4 | InstrumentStudio 2025 Q3 | TestStand 2025 Q3 Resolved Version: InstrumentStudio 2025 Q4 Added: N/A |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.