NI-FGEN 2024 Q4 Known Issues

Overview

This document contains the NI-FGEN known issues that were discovered before and since the release of NI-FGEN 2024 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.

Bug Number

Legacy ID

Description

Details

227853 624206

Reset button not available in MAX or Hardware Configuration Utility for PXIe-5413/5423/5433 waveform generators

Workaround:

Use the niFgen Reset Device VI or niFgen_ResetDevice function.

Reported Version:

NI-FGEN 17.1

Resolved Version:

N/A

Added:

May 8, 2017

227788 631405

Common MAX features are not supported on PXIe-5413/5423/5433 waveform generators: Test Panels, Device Pinouts, Device Routes

Workaround:

Refer to the NI Signal Generators Help for pinout and routes documentation for PXIe-5413/5423/5433 waveform generators.

Reported Version:

NI-FGEN 17.1

Resolved Version:

N/A

Added:

May 8, 2017

227806 642679

PFI lines on PXIe-5450 and PXIe-5451 waveform generators drive a short pulse when NI-FGEN initialize functions are called with the reset device parameter set to False

Workaround:

Set the reset device parameter to True when initializing an NI-FGEN session to a PXIe-5450 and PXIe-5451 waveform generator.

Reported Version:

NI-FGEN 17.1

Resolved Version:

N/A

Added:

May 8, 2017

227817 637708

niFgen ni5433 External Calibration API is not translated to Japanese in LabVIEW

Workaround:

Refer to the NI Signal Generators Help for Japanese documentation of the niFgen ni5433 External Calibration API.

Reported Version:

NI-FGEN 17.1

Resolved Version:

N/A

Added:

May 8, 2017

227814 632366

Initializing and closing an NI-FGEN session in a loop leaks memory for NI-DAQmx-Based Waveform Generators

Workaround:

There is currently no known workaround for this issue.

Reported Version:

NI-FGEN 15.0

Resolved Version:

N/A

Added:

May 8, 2017

227755 644381

Japanese characters not allowed in waveform names or script names on PXIe-5413/5423/5433 waveform generators

NI-DAQmx-based waveform generators allow waveform names with Japanese characters, but on PXIe-5413/5423/5433 waveform generators the NI-FGEN API will report error -1074101561 (0xBFFA82C7): "The script contains an invalid character or symbol. Replace the invalid character with a valid symbol or alphanumeric character."

Workaround:

Change waveform names to use only characters from the English alphabet.

Reported Version:

NI-FGEN 17.1

Resolved Version:

N/A

Added:

May 8, 2017

227744 687100

Synchronization between the PXIe-5413/5423/5433 and the PXIe-5442 does not work in Standard Function output mode and with the PXIe-5442 as the master device

Workaround:

To synchronize the PXIe-5442 and a PXIe-5413/5423/5433 in Standard Function output mode, use the PXIe-5413/5423/5433 as the master device or read the TClk period and then set the minimum TClk period to a higher value by calling niTClk Synchronize.

Reported Version:

NI-FGEN 18.1

Resolved Version:

N/A

Added:

May 17, 2018

227830 641019

Device data underflow failure occurs when generating waveforms with a size of 196 or 200 in Arbitrary Sequence mode on the PXI-5422 waveform generator

The PXI-5422 product documentation states that the minimum supported waveform size is 192 samples and that larger values that are multiples of 4 are also supported. However, a device data underflow error occurs when using waveform sizes of 196 and 200.

Workaround:

Double the number of samples on the host and double the sample rate.

Reported Version:

NI-FGEN 15.0

Resolved Version:

N/A

Added:

May 8, 2017

537276 643582

Write waveform function times out when streaming on PXIe-5413/5423/5433 waveform generators if the sample rate is below 256 kS/s or if the sample rate is below 4.5 MS/s and the allocated waveform size is below 1.2 k samples

Workaround:

Duplicate samples on the host and increase the sample rate of the waveform generator accordingly.

Reported Version:

NI-FGEN 17.1

Resolved Version:

N/A

Added:

May 8, 2017

537291 642393

Options String "DriverSetup=MemorySize:" doesn't simulate memory size correctly on PXIe-5413/5423/5433 waveform generators

The value passed for the MemorySize tag in the Driver Setup string is ignored in simulated instrument sessions. The simulation logic assumes 128 MB of usable memory per channel for PXIe-5413 and PXIe-5423 waveform generators, and 512 MB of usable memory per channel for PXIe-5433 waveform generators.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

NI-FGEN 17.1

Resolved Version:

N/A

Added:

May 8, 2017

2818196

PXIe-5413/23/33 Arb Sequence stepped trigger has poor alignment, compared to initial start trigger, varying as the arb sample rate is changed

The delay for a stepped trigger on the PXIe-5413, PXIe-5423, and PXIe-5433 to occur increases and has more jitter the lower the sample rate.


Workaround:

There is currently no known workaround for this issue.

Reported Version:

NI-FGEN 17.1 | NI-FGEN 2024 Q3

Resolved Version:

N/A

Added:

Sep 26, 2024

1210589, 2256290

NI-FGEN devices may fail under Linux kernel DMA remapping

Attempts to use NI-FGEN devices may fail on Linux kernels that have enabled DMA remapping.  The Linux kernel logs will contain errors similar to the following:
DMAR: [DMA Read NO_PASID] Request device [06:00.0] fault addr 0xb8441000 [fault reason 0x06] PTE Read access is not set
Linux distributions that enable DMA remapping by default include Ubuntu 22.04 with kernel 6.8 or higher and Ubuntu 24.04.

Workaround:

Modify the Linux kernel DMA remapping configuration as outlined in https://www.ni.com/r/iommu-linux.

Reported Version:

NI-FGEN: 21.3

Resolved Version:

N/A

Added:

Sep 27, 2024

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).