This document contains the Battery Test System Software known issues that were discovered before and since the release of Battery Test System Software 2024 Q1. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1596248 |
Test Monitor does not attach large test reports to SystemLinkTestStand report files over 80 MB are not uploaded to SystemLink and attached to the corresponding test result.
Workaround: Ensure your report files are smaller than 80 MB or transfer them manually. Complete the following steps to ensure the report is unique to each DUT if you are using the batch process model:
|
Reported Version: Battery Test System Software Toolkit 2.0 Resolved Version: N/A Added: Sep 1, 2021 |
|
1985043 |
The NI Battery Test System Web Server does not start properly in slow Windows computersThe NI Battery Test System Web Server windows service does not start properly and displays a timeout error in slow computers.
Workaround: Increase the Windows service timeout value following the instructions here: A slow service does not start due to time-out error in Windows
|
Reported Version: Battery Test System Software Toolkit 2022 Q2 Resolved Version: N/A Added: Jun 27, 2022 |
|
2367972 |
Sometimes the Battery Test System Server incorrectly indicates a LabPC is still runningThe Battery Test System Server may incorrectly assume that a Lab PC is still running after executing a test plan if you use one of the following functions:
Workaround: Manually check the status of the LabPC. If the LabPC is not actually running, then disregard the server’s indication.
|
Reported Version: Battery Test System Software Toolkit 2023 Q2 Resolved Version: N/A Added: Jun 5, 2024 |
|
2376473 |
Migrating from Linux to Windows may cause case-sensitivity compatibility issuesYou may encounter errors when migrating from Linux to Windows if your file storage contains paths that only differ in letter case. Windows cannot create paths in this case because it treats paths as case insensitive. For example, Windows interprets ‘Foo’ and ‘foo’ as the same path.
Workaround: NI does not recommend migrating back from Linux to Windows. If you need migration assistance, contact NI technical support.
|
Reported Version: Battery Test System Software Toolkit 2023 Q2 Resolved Version: N/A Added: Jun 5, 2024 |
|
2563231 |
Delay in updating the test station connection status in the Battery Test System Server UIWhen a Lab PC is brought down, the test station connection status becomes disconnected within a few seconds. The test station connection status may take up to 10 minutes to update after bringing the Lab PC back online, despite frequent refreshing.
Workaround: There is currently no known workaround for this issue. |
Reported Version: Battery Test System Software Toolkit 2023 Q2 Resolved Version: N/A Added: Jun 5, 2024 |
|
2673574 |
Uploading large files through the Package Loader tab on the server's UI results in an error or page freezeThe Battery Test System Server has a maximum message size limit when uploading package files through the browser. When the message size exceeds the limit, the system closes the connection with an error. However, the system does not provide a detailed error message, and may leave the page unresponsive. This limit is calculated based on the formula: s ≈ 80 + 3*(n-1) + c where s is the message size in bytes, n is the number of files being uploaded, and c is the total number of characters in all of the relative paths of files selected to upload. Workaround:
|
Reported Version: Battery Test System Software Toolkit 2023 Q2 Resolved Version: N/A Added: Jun 5, 2024 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.