The following items are notable issues fixed between the release of NI-Sync 2022 Q4 and NI-Sync 2023 Q1, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI-Sync.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1760523 |
The 802.1AS Time Reference Is Unavailable on Linux Desktop Distributions after a System RebootOn sporadic occurrences, the 802.1AS time reference is unavailable after a system reboot on Linux Desktop machines. This issue can be verified by running the following command: nitimesynccli --device <deviceslot> --getTrInfo If no information is displayed for 802.1AS, please proceed with the workaround. Workaround: Run the following command in the terminal to restart the TSM service: 'sudo systemctl restart nitsmd.service' |
Reported Version: NI-Sync 21.8 Resolved Version: NI-Sync 2023 Q1 Added: Nov 15, 2022 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.