The following items are notable issues fixed between the release of Battery Test System Software 2022 Q4 and Battery Test System Software 2023 Q2, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of Battery Test System Software.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1873086 |
Battery test package files cannot be removed once submitted through the BatteryTestPackageLoaderOnce battery tests package files are submitted through the BatteryTestPackageLoader, they cannot be removed from the database of the server.
Workaround: Fixed in the Battery Test System Software 2023 Q2.
If using an older version, submitting a package file with the same name updates the existing configuration. In this case, the old version is archived and used only by existing test plans. Submitting a configuration with a different name results in a new test plan. |
Reported Version: Battery Test System Software Toolkit 2022 Q2 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: Jun 27, 2022 |
|
2168173 |
Embedded Data Logger settings are ignored when using Size in the base propertyThe BTS Server ignores the segmenting settings for EDL.xml files that use "Size" as their Base, such as in:
<FileSegmenting Interval="60" Base="Size" Enabled="true"/> Workaround: Fixed in the Battery Test System Software 2023 Q2.
If using an older version, use "Time" instead of "Size" for the Base in the FileSegmenting element of the EDL.xml, such as in: <FileSegmenting Interval="60" Base="Time" Enabled="true"/> |
Reported Version: Battery Test System Software Toolkit 2022 Q2 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: Oct 24, 2022 |
|
2168457 |
Test station files must not have more than one NI-VCOM (PROVEtechRBS) instrumentA test station file (.teststation) with more than one NI-VCOM (PROVEtechRBS) instrument will be accepted by the package loader application and will make the test station not work properly.
Workaround: Fixed in the Battery Test System Software 2023 Q2.
If using an older version, do not add more than one NI-VCOM (PROVEtechRBS) instrument in a test station file (.teststation). |
Reported Version: Battery Test System Software Toolkit 2022 Q2 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: Oct 24, 2022 |
|
2170408 |
Package loader cannot intake packages due to an error writing to the EntityFileAsset.index fileIntaking test packages through the package loader application may, in some cases, result in the following error: "The process cannot access the file '\\?\C:\bts_production_storage\EntityFileAsset.index' because it is being used by another process."
Workaround: Fixed in the Battery Test System Software 2023 Q2.
If using an older version, run the package loader command again. |
Reported Version: Battery Test System Software Toolkit 2022 Q2 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: Oct 24, 2022 |
|
2174258 |
The Embedded Data Logger and SystemLink custom devices display error 1162 when opening their right-click menusThe Embedded Data Logger and SystemLink custom devices display Error 1162: "LabVIEW: (Hex 0x48A) Cannot find one or more tags" when opening their right-click menus in the VeriStand System Explorer.
Workaround: Fixed in the Battery Test System Software 2023 Q2.
After restarting, return the files to their original locations after accessing the required right-click menu options and closing VeriStand.
|
Reported Version: Battery Test System Software Toolkit 2022 Q2 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: Oct 24, 2022 |
|
2174304 |
Some DUT Ports are not published to SystemLink as tagsSome NI-VCOM (PROVEtechRBS) channels are not published to SystemLink as tags.
Workaround: Fixed in the Battery Test System Software 2023 Q2. |
Reported Version: Battery Test System Software Toolkit 2022 Q2 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: Oct 24, 2022 |
|
2321822 |
The list of users in the Web UI does not display more than 50 usersThe Battery Test System Server Web UI does not display more than 50 users in the table, which disables administrators to change the user roles of servers that host more than 50 users. Workaround: Fixed in the Battery Test System Software 2023 Q2.
|
Reported Version: Battery Test System Software Toolkit 2022 Q4 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: May 30, 2023 |
|
2267256 |
Black Box Recorder "Writing" channel does not change to True when a trigger is receivedThe Black Box Recorder custom device sets the "Writing" channel to True when it starts when the file starts to be written. Instead, it should remain True from the moment the Trigger is received, and until all data has been acquired.
Workaround: Fixed in the Battery Test System Software 2023 Q2.
|
Reported Version: Battery Test System Software Toolkit 2022 Q4 Resolved Version: Battery Test System Software Toolkit 2023 Q2 Added: May 30, 2023 |