This document contains the WLR Test Software known issues that were discovered before and since the release of WLR Test Software 22.5. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
2141796 |
Actual Stress Time Values Logged in the CSV Report during A Stress Step Run Are Not as Accurate as the Final ValueWhen generating a CSV report, the actual stress time is logged in every datalogging interval during a stress step run and after the step finishes. Due to different calculation methods, the intermediate values are not as accurate as the final value. Workaround: Use the final value for analysis. Use the intermediate values only as rough references when the test is not completed normally.
|
Reported Version: WLR Test Software 22.5 Resolved Version: N/A Added: Sep 29, 2022 |
|
2116213 |
The WLR Test Soft Front Panel Goes into Not Responding State when Zooming in for a Long Time in the Graph View on the Operator Interface PaneOn the RESULTS tab of the Operator Interface pane, when you use continuous zoom in for a long time in the graph view, the WLR Test Soft Front Panel may go into not responding state. Workaround: End task in the Windows Task Manager. To avoid this issue, NI recommends that you do not use continuous zoom in for a long time or that you use other zoom in options.
|
Reported Version: WLR Test Software 22.5 Resolved Version: N/A Added: Sep 29, 2022 |
|
2157539 |
Error 91 Occurred when Checking Data in the Result Viewer after Running the Stress N Terminal DUT Step where the Stress Mode is Custom or Linear Bias Sweep and the Measurement Mode Is Disable MeasurementIn the WLR Test Soft Front Panel, after running a test plan that includes a Stress N Terminal DUT step when the stress mode is Custom or Linear Bias Sweep, and the measurement mode is Disable Measurement, if you view the results in the Result Viewer, and then select a different device ID, error 91 occurred and was reported in a dialog box indicating that the data type of the variant is not compatible with the data type wired to the data type input. Workaround: Click Continue to close the dialog box and keep using the WLR Test Soft Front Panel. The Result Viewer does not display any data when Disable Measurement is set in the stress configurations, and this error does not impact the sequence execution.
|
Reported Version: WLR Test Software 22.5 Resolved Version: N/A Added: Sep 29, 2022 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.