The following items are notable issues fixed between the release of NI LabVIEW Instrument Design Libraries for High Speed Serial Instruments 21.0 and NI LabVIEW Instrument Design Libraries for High Speed Serial Instruments 21.5, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI LabVIEW Instrument Design Libraries for High Speed Serial Instruments.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1527655 |
ni659XR Driver Interface Public.lvlib:Open Session.vi fails to deploy on Linux RTDuring the deploying process to the Linux RT target you will see the following error:
Workaround: Instead of using Open Session.vi, pass the resource name to serialNumFromName.vi to obtain the serial number of the resource and then pass the serial number to rioInterfaceNumFromSerialNum.vi to get a RIO interface number. These VIs are present in the same library (ni659XR Driver Interface Public.lvlib). |
Reported Version: LabVIEW Instrument Design Libraries for High-Speed Serial Instruments 21.0 Resolved Version: LabVIEW Instrument Design Libraries for High-Speed Serial Instruments 21.5 Added: Jul 23, 2021 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.