The following items are notable issues fixed between the release of NI CompactRIO 2022 Q3 and NI CompactRIO 2022 Q4, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI CompactRIO.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
2062084 |
CompactRIO Single Board Controllers with NI-DAQmx Support and Real-Time Scan Resources Will Fail to Compile Bitfiles on LabVIEW 2022 Q3Compilation failures with timing violations are likely to occur for users with C Series modules under Real-Time Scan Resources.The targets affected are sbRIO-9603, sbRIO-9608, sbRIO-9609, sbRIO-9626, sbRIO-9629, sbRIO-9638. Workaround: Use LabVIEW 2021 or earlier for these targets
|
Reported Version: NI CompactRIO 2022 Q3 Resolved Version: NI CompactRIO 2022 Q4 Added: Aug 2, 2022 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.