Archived: DIAdem 11.1 (European Version) Bug Fixes

NI does not actively maintain this document.

This content provides support for older products and technology, so you may notice outdated links or obsolete information about operating systems or other relevant products.

Overview



The following list contains the CAR IDs and the descriptions of the problems solved between DIAdem 11.0 and DIAdem 11.1. Use the CAR ID to check in the list whether the issue has been fixed.
CAR IDDescription

General

113526If you enabled the DIAdem 10.1 path behavior in the Compatibility dialog box and then changed the library path, DIAdem then changed the user path accordingly.
131783When recognizing target channels DIAdem now includes replacement signs for groups and channels. Refer to Name Conventions in the DIAdem help for more information.
155574The Val function did not convert a string with the NoValue value to NULL.
157756The DesktopChanged variable now also checks whether the bar definition was changed with the BarManager.
161829When DIAdem launched with the parameter /S some system files were not transferred. Therefore the program interface displayed at various places question marks instead of the correct symbols.
167172In the units catalog, decimal places were added to conversion factors that are dependent on the number Pi. Thus the conversion is more accurate.

Data Portal

157188When DIAdem deleted a channel group, DIAdem sometimes defined a different channel group as the default group.

NAVIGATOR

117765When a channel was moved, the ChannelGroup property might still have referred to the original channel group.
126769If DIAdem edited a file with the DataFileHeaderAccess method and deleted a custom property with the RootPropDel method, this custom property still existed later.
140702If the Open in Explorer context menu was used in the file browser, files could not be opened in the Explorer if a path, for example, contained a comma.
143097The LoadQuery method of the NAVIGATOR script interface did not display an error message if an error occurred.
147111In the DataFinder Server Edition and in DIAdem encrypted DataPlugins could not be exported.
149021If the date/time values were imported in milliseconds in the ASCII Import filter and both second digits had the value 0, it could happen that the date was set to 1/1/0000.
150357The selective storage of DIAdem DAT files was incorrect if the minimum and the maximum of the channel were the same, and the channel also contained NoValues. In this case DIAdem saved the channel as an implicit channel and all NoValues were lost.

VIEW

117523If a Band cursor was played to the end and then was restarted, the distance between the two cursor lines changed.
117726The display of a 3D model resulted in a shift if a normalization of the channel values was executed with different value ranges of the channels.
118301If a section of a curve that did not contain values was selected with a Frame cursor, it could happen that not all points were included when flags were set for this section.
121571A 3D model display was mirrored. A button has been included with which you can specify the rotational direction of the coordinate system.
137895A curve was sometimes incorrectly displayed if parts of the curve were at the edge of a clipping range.
140917Using non-existent enumeration terms in the VIEW script interface did not produce an error message.
144007The attempt to delete sheets with a non-existing index, could lead to a crash.
144246If channel names were entered manually in the 2D Axis System - Display dialog box, DIAdem did not display these channels before the display was refreshed.
145138The use of the script interface in DIAdem VIEW could lead to a crash not only to an error message if a parameter was not set.
161812If only the font was changed in a textbox, DIAdem did not retain the change after the dialog box closed.
162725If a display dialog box was cancelled, DIAdem sometimes did not display the worksheet before the next refresh.
164051If values were added or appended to a table, the last row of the block end could not have a value greater than the maximum channel length plus 10 values.

ANALYSIS

114084In the dialog box for configuring the rainflow results, the labels LCC and RPC were swapped.
114102The MatExtremeValues command returned the values-1E300 or 1E300 if the matrix only contained NoValues.
115763The contour calculation is faster now for data sets that contain many y-values that are identical to the y-maximum or to the y-minimum. The calculation can now also be terminated.
118925In DIAdem Version 11.1 and later versions, DIAdem no longer inserts a value with the same magnitude but the opposite sign, for the first reversal point of a load-time function, in Rainflow Classification. This behavior deviates from the stipulations of the brochure FVA 0/14, paragraph 1.2.4.
129796The type of amplitude calculation (FFTAmplType) was not recorded when a order analysis in the frequency range was executed in the recording mode.
138076In some cases, the optional index channel (FFTIndexChn) was not generated completely in the calculation of several FFTs.
142822If the data in the 3D displays Surface and Characteristic Diagram was triplet data, a wrong error message was sometimes displayed.
145984In the Calculator it sometimes happened that text assignments which contained a colon were incorrectly recorded, depending on the selected recording mode.
148665The FFC and NIC calculation is different to DIAdem 11.0 and earlier versions. DIAdem now uses the cumulative calculation of all peaks according to the EuroNCAP. You can use time at level for a continuous calculation within a peak.
151416When NoValues were replaced by a different value, the characteristic values of channels that were processed but did not contain NoValues were also changed.
152082The x-channels of the bottom and the top envelope curve were incorrectly named if the y-input channel contained NoValues.
153367After an incorrect evaluation of an expression in the Calculator, no further expression could be evaluated.
155177The THIV calculation might have returned incorrect results.
164937If an error occurred in a compound classification, DIAdem did not delete the already generated result channels.
167167The PHD calculation sometimes returned incorrect results.

REPORT

118295In 2D-axis systems with mirrored x-axes and y-axes the scaling would change to linear, if the x-axes texts were selected in the layout and deleted with <Del>.
124134Now you can use the PicPalCtrlHSL variable to specify boundary colors in the global palette.
129531Empty channels sometimes occurred in curve transformations.
129778The setting Align subaxis ticks to grid sometimes returned different results when the layout was refreshed.
130139If the data layer or the graphics layer was disabled a configuration dialog box then opened and this dialog box was then cancelled, DIAdem enabled the data layer or the graphics layer.
137430Inserting an Excel table into a text object via the clipboard could lead to a crash.
141562Using the keyboard combination <CTRL+S> to save a report did not function if the target path contained a & character.
146774If a frame with a shadow was used in a report, the printout and the PDF export was incorrect.
148349Using the PicPDFExport command to append pages could lead to previously exported pages missing in the PDF document.

SCRIPT

117320The tooltips of variables did not function if the value to be displayed contained XML code.
125069Opening DIAdem SCRIPT is now faster.
130156If a vector only contained NoValues when the ArraysToChannels command was used, DIAdem generated a numeric channels with zeros. Now DIAdem generates NoValuesinstead.
131480The ChnAreaInsert0 command did not function if there was a gap between the channel end and the position where the value was to be inserted.
134544If the MsgType parameter of the MsgBoxDisp command had the value MsgTypeError, DIAdem did not terminate this script.
135671The ArraytoChannels command does not support the VT_Decimal data type, which, for example, is provided by ORACLE data bases.
143745AUT scripts did not generate result channels automatically.
151039The GraphObjChnClear command only deleted curves but not constants.
154111An error occurred when a property was generated and filled with a name that contained invalid characters, for example, a digit at the beginning. Invalid characters are now replaced by an underscore.
156641If you used the GraphSheetMove command to move worksheets and then used the PicPDFExport command to print all worksheets to a PDF file, the alignment of the worksheets was sometimes wrong.
156793If the display of recent files was disabled in Windows, the SUD Editor sometimes crashed.
157414The ChnConvertToUnitSet command did not correctly convert the unit of channels that existed multiple times in the channel list.
97604In the Debug mode the tooltip of a variable did not appear until the cursor moved away from the selection and then moved back over the selection.

DAC

115430Sound output led to memory leaks.
116167In the Script DAC driver only the first digit of the linear specification of the format was evaluated if the UDI function Parse was used for a format specification.
129891If the time zone on the client computer was set without summer time and the automatic adjustment to summer time was enabled, the connected OPC server was sometimes declared not accessible.
132637If the filename for data to be saved contained a leading blank, the measured data could then not be loaded again. Blanks are now trimmed, like in Windows Explorer.
141963In the storage block dialog box a calculation could not be executed if the number of values for the storage cycle was entered as a variable.
144511If the Val function was used in formula blocks, an error occurred when the measurement started.
147211An error sometimes occurred when the variables for the GFSNIDAQ output blocks were written or read.
160581In measurements with SCXI modules and DAQmx, error messages sometimes occurred during the measurement preparation because the SCXI channels were not assigned to the correct DAQ tasks.
164926The correct configuration of the dialog box for the selection of an OPC server did not always lead to the correct connection with the respective OPC server.
167461The script driver now also supports scripts that are in the network.

USI

115796ATFX files with "external components" are now supported better.
118712If you saved a TDMS file on a computer and then loaded the file onto a computer with a different summertime setting, a time offset could occur.
143720It sometimes happened in the ASAM data service that, if you used a laptop that was connected to a second monitor and you displayed a dialog box on the second monitor, that the dialog box could no longer display once the second monitor was disconnected.
147774The DIAdem AOP3 DataPlugin for ASAM ODS now also supports Santorin 3.4 Server from the company AVL LIST GMBH.
161278In the AOP3 DataPlugin the automatic recognition of the server version sometimes resulted in an incorrect search behavior for version 3.2 servers.
164020If the <> operator was used for text attributes in the ASAM data service, this search condition was ignored by the AOP plugin.

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).