779620-01
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
Overview
The PXI-6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32-bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control.
The PXI-6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI-6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
PXI-6233 Details
Part Numbers (1) Price | 779620-01 |
|---|---|
| NI Lead Time | 16-17 weeks |
| Current Flow Direction | Sinking Output |
| Maximum Number of Single-Ended Analog Input Channels | 16 |
| Analog Input Resolution | 16 bits |
| Simultaneous Sampling | No |
| Maximum Sample Rate | 250 kS/s |
| Analog Input Absolute Accuracy | 3100 μV |
| Number of Counters/Timers | 2 |
| Number of Analog Output Channels | 2 |
| Maximum Analog Update Rate | 500 kS/s |
| Bus Connector | PXI Hybrid |
| Number of Bidirectional Digital Channels | 0 |
| Electrical Signal Measured | Voltage |
| Analog Input FIFO Buffer Size | 4095 samples |
| Maximum Number of Differential Analog Input Channels | 8 |
| Reconfigurable | Yes |
| Number of Analog Input Channels | — |
| Maximum Digital Update Rate | — |
| Operating Temperature Range | — |
| Bus Connection | PXI Hybrid |
| Digital I/O Isolation | — |
| Digital I/O Logic Levels | — |
| Front Connection Type | D-SUB(1) |
| Maximum Clock Rate | — |
| Number of Digital Input Only Channels | 6 |
| Number of Digital Output Only Channels | 4 |
| Number of External Clock Inputs | — |
| Relay Type | — |
| Signaling Type | — |
| Supports Peer To Peer Streaming | — |
| Analog Input Voltage Range | -0.2 V to 0.2 V -1 V to 1 V -5 V to 5 V -10 V to 10 V |
| Analog Input Isolation | — |
| Filtering | — |
| Number of Current Output Channels | — |
| Number of Voltage Output Channels | — |
| Analog Output Voltage Range | -10 V to 10 V |
| Output Current Range | — |
| Analog Output Isolation | — |
| Analog Output Resolution | — |
| Analog Input Maximum Absolute Accuracy | — |
| Product Description | PXI-6233, 60 V Isolated (16 SE AI, 2 AO, 6 30V DI, 4 30V DO) |
PXI-6233 Accessories and Software
- Product (Part Number)DescriptionRecommended use casesFlexLogger Professional (785748-3501)FlexLogger Professional, Subscription License, Download
Recommended for automated, extensible data logging with NI data acquisition (DAQ) hardware. Automate tests using alarms, triggers, and events, and expand capabilities with plug-ins.
Key Features
- Multichassis synchronization—Synchronize multiple NI chassis for accurate, time-aligned measurements across high channel counts.
- Logging triggers—Start, stop, or segment data recording automatically based on sensor thresholds or other conditions to capture only what matters.
- Events—Respond to specific occurrences during a test, such as activating equipment when a condition is met (for example, start cooling fans when temperature exceeds a limit).
- Automation APIs—Control and monitor FlexLogger from external applications (Python, NI LabVIEW, or NI TestStand), enabling integration into larger automated test systems.
- Calculation channels—Perform real-time math on acquired data (averages, RMS, custom formulas) to track derived measurements as the test runs.
- Plug-ins—Extend FlexLogger with custom LabVIEW or Python plug-ins to integrate third-party hardware, perform custom analysis, or connect to lab systems.
- CAN/LIN logging—Acquire and log automotive network data alongside sensor measurements for complete vehicle or subsystem testing.
LabVIEW+ Suite (788509-35)NI LabVIEW+ Suite, Subscription License, DownloadRecommended for engineers building full test and validation systems where modular code development and higher-level frameworks are needed to accelerate development for shorter time to market.
The LabVIEW+ Suite includes the following products:
- NI LabVIEW—Provides a graphical programming environment for test system development, enabling connectivity to any instrument and fully integrated user interfaces.
- NI TestStand—Eliminates the need for time-intensive in-house sequencer development and maintenance by providing an off-the-shelf test management software for validation and production test.
- NI DIAdem—Saves engineers hundreds of hours of manual data analysis and report creation with automation.
- NI FlexLogger™ software—Simplifies data acquisition and data logging with interactive measurement setup for NI DAQ hardware.
- NI InstrumentStudio™ software—Provides a central location for configuration, measurement, and automation.
Resources
Support
Request support
You can request repair, schedule calibration, or get technical support. A valid service agreement may be required.
NI Community
Ask questions, explore solutions, and participate in discussions with other NI Community members.
KnowledgeBase
Search for answers to frequently asked questions and troubleshooting tips for common errors written by NI engineers.
Online training
Access hundreds of self-paced lessons, application-focused learning paths, and get started with product set-up tutorials.