VeriStand 2020 Known Issues

Overview

This document contains the VeriStand 2020 known issues that were discovered before and since the release of VeriStand 2020. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.

Bug Number

Legacy ID

Description

Details

115960 572887

Setting the Frame Type Option in the Raw Data Frame Configuration Page Has no Effect

As the frame type is pulled from the XNET database, the system definition setting does not affect the XNET configuration.

Workaround:

Set the frame type in the XNET database. Do not use the Raw Data Frame Type Configuration option in the system definition.

Reported Version:

VeriStand 2014

Resolved Version:

N/A

Added:

Jan 17, 2020

117765 522678

Adding an FPGA Target to the System Definition via the API Will Fail to Add the Parameters Section of PWM Channels

When using the System Definition API to add an FPGA target to a system definition file, the Parameters section typically included with PWM channels is excluded.

Workaround:

Add the FPGA target manually to the system definition using System Explorer.

Reported Version:

VeriStand 2014

Resolved Version:

N/A

Added:

Jan 17, 2020

1015885

Deploying a LabVIEW Model Containing Array Inports, Outports or Parameters to a Linux RT Target Results in Error

Description:

If a LabVIEW model has array inports, outports or parameters, and the "Maintain as vector channel" option is enabled, deploying to a Linux Real-Time target will results in a size mismatch error. If the array of cluster with an array is an inport or outport, the error is -307702. For parameters, the error is -307728.


Workaround:

In the Tools>>Options menu of the Generate Model from VI Settings dialog , select (Legacy) Use Nx1 Vectors.

Reported Version:

VeriStand 2019 R2

Resolved Version:

N/A

Added:

May 6, 2020

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).