ID | Fixed Issue |
---|---|
149703 | Deploying a VI to a target that was running VeriStand unsets it as startup exe. Must reinstall to fix |
176352 | Import settings checkbox for Models can not be changed by clicking the boolean text. |
185544 | Graph control background plot color cannot be changed |
187134 | Need to expose documentation for .net dll in 2010 |
206801 | Temp Gauge scale min and max do not update |
208943 | TDMS Viewer in VS does not show initial timestamp correctly |
209565 | Document XML Schema for NI VeriStand Custom Devices |
222546 | Model inports and outports cannot be configured with a default value |
233003 | Associate nivssdf and nivsproj with veristand so you can launch from file |
240196 | Examples may search for VeriStand API VIs when first opened |
240398 | Unclear error thrown when using daq and fpga in an unidentified chassis |
241159 | Model parameter manager takes a while to close, locking user out of sys explorer |
241408 | Built in thermocouple scaling does not work for 9219 |
242105 | Custom Device Path property does not work on VxWorks |
243455 | Stop Macro Player function hangs indefinitely if Macro was paused, not running |
244193 | Counter frequency channels created with invalid min and max Hz of zero |
244558 | Clicking add data folder under reflective memory throws error and fails |
245381 | Import XNET Frames doesn't automatically select Signals if the hierarchy is deeper than 2 |
246557 | VeriStand 2010 Import .dbc file |
247356 | Parameter values not updated if model changes value but it is not refreshed in System Explorer |
247357 | Model Parameter manager slow with large set of parameters |
247362 | LVModel generation fails for inputs with deep clustering |
248320 | Reset Dependencies does not work properly |
249210 | MDL files linked by relative path crash MATLAB® |
251326 | XNET bus monitor does not display frames if raw frame logging is used |
254228 | Custom devices added to a single target are deployed to all targets in a system definition |
254231 | VeriStand can download dependent file multiple times to same target |
254899 | Veristand: Degradation in performance the more CAN channels added |
255534 | Hidden Aliases Still Show in the Workspace |
257917 | delete multiple items doesn't properlly react to ok / cancel |
258756 | FPGA scaling with negative integer wordlength for FXP Data always produces Inf values |
275996 | Missing ClientAPI Assembly in Visual Studio 2010 Add Reference Dialog |
276513 | Manifest not embedded in DLL when building a custom model DLL with VC 9.0 or 10.0 for NI VeriStand |
282611 | Veristand 2010 - Can't reconnect to remote target after network goes down then back up if anything is deployed |
282669 | Opening a nivstest with a generator mapped to an invalid alias throws cryptic error |
283556 | Inline the get set channel value by reference VIs |
283910 | NIVS 2010 Holds Onto one Exported Reflective Memory Channel if RM Channels Were Ever Exported |
284264 | Scroll Bar in XNET Frame List Window is not clickable |
284397 | Running a project programatically doesn't load items linked in the system defintion with a relative path |
286720 | Large Alias Files Fails to Load in Veristand |
286762 | Veristand 2010 - Can't deploy system definition file that has two targets while one target has a XNET resource |
287203 | Calling Get Parameter while Gateway is Connection will result in Get Parameter to Return Erroneous Data |
287794 | Default indicator units do not appear when opening workspace |
288388 | Large models with many parameter take a long time to load |
289232 | Bus monitor: Delayed Display |
290868 | NI VeriStand Stimulus Profile Editor can not be closed, if mapping dialog closed by "X" |
291291 | csv file with mixed integer and float data gets imported as all integers, truncating the floats |
291398 | Host TDMS logging creates very fragmented files |
293327 | Importing Models is different if you use the VeriStand API vs using the System Explorer |
293820 | System Explorer API Model Constructor Doesn't Import all Model Parameters |
295128 | graphs leave "invalid" tag prepended to signal name even after the signal becomes valid again |
295710 | Reflective Memory Data Channels at Some Addresses (or Address Ranges) Cause Unacceptable Latency in RT Engine |
298866 | If two custom devices use the same page GUID, all tree browsers fail and some crash |
299092 | Can't add more than two counters to an existing DAQ MIO device |
299103 | Pressing delete while editing the legend text deletes the channel |
300280 | Decimated model only has one tick to finish before it's late |
301749 | Veristand sinewave.c Example Does Not Support ANSI C |
305597 | Can't delete missing custom devices |
306199 | Veristand returns error 63 when deploying to target that has the wrong vstand engine version |
306847 | Reflective memory channels are not faultable |
307207 | Error 1172 from adding LabVIEW model with outport name that includes a new line character |
308014 | Can't set default colors on new controls |
313529 | Faulting a specific model channel faults the wrong channel. |