Filtered Results

Reads a waveform that contains a single sample from a task that contains a single analog input channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx ...

Reads a waveform from a task that contains a single analog input channel. You must specify the duration, in seconds, for the waveform. LabVIEW NXG does not support FPGA devices Not supported in VIs that ...

Reads a waveform from a task that contains a single analog input channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Analog Wfm 1Chan NSamp).vi ...

Reads one or more raw, 16-bit signed integer samples from a task. Use this instance with devices that use 16-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 32-bit signed integer samples from a task. Use this instance with devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 8-bit signed integer samples from a task. Use this instance with devices that use 8-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support FPGA ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 32-bit unsigned integer samples from a task. Use this instance with devices that use 32-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 8-bit unsigned integer samples from a task. Use this instance with devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more floating-point samples from a counter task. Use an instance that reads a floating-point value when NI-DAQmx scales counter samples to a floating-point value, such as for frequency and ...

Reads one floating-point sample from one or more counter tasks. Use an instance that reads a floating-point value when NI-DAQmx scales counter samples to a floating-point value. LabVIEW NXG does not support ...

Reads one or more 32-bit unsigned integer samples from a counter task. Use an instance that reads 32-bit unsigned integers when NI-DAQmx returns counter samples unscaled, such as for event counting. LabVIEW ...

Reads an unscaled 32-bit unsigned integer sample from one or more counter tasks. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter 1D U32 ...

Reads one or more floating-point samples from one or more counter tasks. Use an instance that reads a floating-point value when NI-DAQmx scales counter samples to a floating-point value. LabVIEW NXG does ...

Reads one or more raw, 32-bit signed integer samples from a task. Use this instance with devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...

Sets up external calibration for an NI 9219 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Setup 9219 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads the specified value from the ADC on the specified physical channel. This module requires a sweep of adjustment points obtained from the DAQmx Get 9244 Calibration Adjustment Points node. LabVIEW ...

Reads one or more raw, 8-bit unsigned integer samples from a task. Use this instance with devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Writes the specified binary value to the DAC on the specified physical channel. This module requires a sweep of DAC values obtained from the DAQmx Get 9263 Calibration Adjustment Points node. LabVIEW NXG ...

Showing 161-180 of 2006 results
9 of 101 pages