The following figure shows how to position strain gage resistors in an axial configuration for the full-bridge type III. The full-bridge type III configuration only measures the axial configuration. Full-bridge ...

On an X Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

Amplification is a type of signal conditioning that improves accuracy in the resulting digitized signal by increasing signal amplitude relative to noise. For the highest possible accuracy, amplify the ...

Thermocouples are the most commonly used temperature sensors. A thermocouple is created when two dissimilar metals touch and the contact point produces a small open-circuit voltage that corresponds to ...

Quantization error is the inherent uncertainty in digitizing an analog value as a result of the finite resolution of the conversion process. Quantization error depends on the number of bits in the converter, ...

Writes a single 8-bit unsigned integer sample to each channel in a task that contains one or more digital output channels. Use an instance that writes 8-bit unsigned integers for devices with up to eight ...

Writes new pulse frequency and duty cycle pairs to a counter output task that contains a single channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx ...

Specifies in ohms the resistance of the bridge while not under load. Not supported Not supported in VIs that run in a web application 17EC attr17EC.html

Specifies whether to ground the internal DAC reference. Grounding the internal DAC reference has the effect of grounding all analog output channels and stopping waveform generation across all analog output ...

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 2274 attr2274.html ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 21FC attr21FC.html

Specifies the logic level behavior on the input line. Not supported Not supported in VIs that run in a web application Logic Level Pull-up 16064 High logic. None 10230 Supply no excitation to the channel. ...

Writes a single sample of Boolean values to a task that contains a single digital output channel. The channel can contain one or more digital lines. LabVIEW NXG does not support FPGA devices Not supported ...

Specifies an array of coefficients for the polynomial that converts physical values to electrical values. Each element of the array corresponds to a term of the equation. For example, if index three of ...

Indicates the coefficients of a linear equation that NI-DAQmx uses to scale values from a voltage to the native format of the device. Each element of the array corresponds to a term of the equation. The ...

Specifies the kind of the waveform to generate. Not supported Not supported in VIs that run in a web application Sine 14751 Sine wave. Triangle 14752 Triangle wave. Square 14753 Square wave. Sawtooth 14754 ...

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 21EA attr21EA.html ...

Specifies in seconds the length of time to measure the frequency of the signal if CI.Freq.MeasMeth is High Frequency with 2 Counters. Measurement accuracy increases with increased measurement time and ...