Specifies the rate of the Sample Clock Timebase. Some applications require that you specify a rate when you use any signal other than the onboard Sample Clock Timebase. NI-DAQmx requires this rate to calculate ...

Specifies a hysteresis level in the units of the measurement. If Ref.AnlgEdge.Slope is Rising, the trigger does not deassert until the source signal passes below Ref.AnlgEdge.Lvl minus the hysteresis. ...

Specifies in the units of the measurement the threshold at which the Reference Trigger occurs. Use Ref.AnlgEdge.Slope to specify on which slope to trigger at this threshold. Not supported Not supported ...

Specifies on which slope of the source signal the Reference Trigger occurs. Not supported Not supported in VIs that run in a web application Rising 10280 Trigger on the rising slope of the signal. Falling ...

Specifies the action to take when the onboard memory of the device becomes empty. Not supported Not supported in VIs that run in a web application Halt Output and Error 14615 Stop generating samples and ...

Specifies the terminal to which to route the Sample Clock Timebase. Not supported Not supported in VIs that run in a web application 18F9 attr18F9.html

Specifies the number of samples to acquire or generate for each channel if SampQuant.SampMode is Finite Samples. If SampQuant.SampMode is Continuous Samples, NI-DAQmx uses this value to determine the buffer ...

Specifies the type of sample timing to use for the task. Select Sample Clock when a hardware signal (usually a clock) must acquire or produce samples. To perform buffered edge counting, for example, select ...

Specifies the coupling for the source signal of the trigger if the source is a terminal rather than a virtual channel. Not supported Not supported in VIs that run in a web application AC 10045 Alternating ...

Specifies in seconds the amount of time to sleep after checking for available samples if WaitMode is Sleep. Not supported Not supported in VIs that run in a web application 22B0 attr22B0.html

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2EEC attr2EEC.html

Specifies the coupling for the source signal of the trigger if the source is a terminal rather than a virtual channel. Not supported Not supported in VIs that run in a web application AC 10045 Alternating ...

Specifies whether to apply a digital filter to the digital output of the analog triggering circuitry (the Analog Comparison Event). When enabled, the analog signal must stay above or below the trigger ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 2EE2 attr2EE2.html

Specifies in hertz the rate of the digital filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 2EE4 attr2EE4.html ...

Specifies the terminal of the signal to use as the timebase of the digital filter. Not supported Not supported in VIs that run in a web application 2EE3 attr2EE3.html

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. Not supported Not supported in VIs that run in a web application 2EE5 attr2EE5.html

Specifies a hysteresis level in the units of the measurement or generation. If Start.AnlgEdge.Slope is Rising, the trigger does not deassert until the source signal passes below Start.AnlgEdge.Lvl minus ...

Specifies at what threshold in the units of the measurement or generation to start acquiring or generating samples. Use Start.AnlgEdge.Slope to specify on which slope to trigger on this threshold. Not ...

Specifies on which slope of the trigger signal to start acquiring or generating samples. Not supported Not supported in VIs that run in a web application Rising 10280 Trigger on the rising slope of the ...

Specifies the name of a virtual channel or terminal where there is an analog signal to use as the source of the Start Trigger. Not supported Not supported in VIs that run in a web application 1398 attr1398.html ...

Specifies an array that describes the couplings for the corresponding source signal of the trigger if the source is a terminal rather than a virtual channel. Each element of the array corresponds to a ...

Specifies an array of hysteresis levels in the units of the measurement or generation. If the corresponding element of Start.AnlgMultiEdge.Slopes is Rising, the trigger does not deassert until the source ...

Specifies an array of thresholds in the units of the measurement or generation to start acquiring or generating samples. Each element of the array corresponds to a source in Start.AnlgMultiEdge.Srcs and ...

Specifies an array of slopes on which to trigger task to start generating or acquiring samples. Each element of the array corresponds to a source in Start.AnlgMultiEdge.Srcs and an element in each of the ...

Specifies a list and/or range of analog sources that are going to be used for Analog triggering. Each source corresponds to an element in each of the Analog Multi Edge property arrays, if they are not ...

Specifies the lower limit of the window. Specify this value in the units of the measurement or generation. Not supported Not supported in VIs that run in a web application 1402 attr1402.html

Specifies whether to apply a digital filter to the digital output of the analog triggering circuitry (the Analog Comparison Event). When enabled, the analog signal must stay within the trigger window for ...

Specifies the period of time in seconds after the task starts during which the device may trigger. Once the window has expired, the device stops detecting triggers, and the task will finish after the device ...

Specifies in hertz the rate of the digital filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 2F02 attr2F02.html ...

Showing 181-210 of 2179 results
7 of 73 pages