Filtered Results

What Is Device Calibration? Device calibration consists of verifying the measurement accuracy of a device and adjusting for any measurement error. Verification consists of measuring the performance of ...

In NI-DAQmx 8.0 or later, you can set up distributed applications to combine remote data applications using the NI-DAQmx I/O Server. For instance, you can configure a central computer to monitor other ...

Reads one or more pairs of pulse high and low times from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter 1D Pulse ...

Reads one or more raw, 8-bit unsigned integer samples from a task. Use this instance with devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads an array of Boolean values from a task that contains a single digital input channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Digital ...

Saves the specified local or global channel to MAX as a global channel. You must specify both the local or global channel to save and a task that contains that channel. LabVIEW NXG does not support FPGA ...

Writes one or more 8-bit unsigned integer samples to a task that contains one or more digital output channels. Use an instance that writes 8-bit unsigned integers for devices that have up to eight lines ...

Specifies in ohms the load impedance connected to the analog output channel. Not supported Not supported in VIs that run in a web application 121 attr121.html

Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 3099 attr3099.html

Specifies a user-defined description for the channel. Not supported Not supported in VIs that run in a web application 1926 attr1926.html

Specifies how to open the TDMS file. Not supported Not supported in VIs that run in a web application Open 10437 Open an existing TDMS file, and append data to that file. If the file does not exist, NI-DAQmx ...

Specifies the type of trigger to use to pause a task. Not supported Not supported in VIs that run in a web application Analog Level 10101 Pause the measurement or generation while an analog signal is above ...

Indicates in samples per channel the amount of available space in the buffer. Not supported Not supported in VIs that run in a web application 1460 attr1460.html

Specifies whether to apply a digital filter to the digital output of the analog triggering circuitry (the Analog Comparison Event). When enabled, the analog signal must stay above or below the trigger ...

Specifies the terminal of the signal to use as the Sample Clock. Not supported Not supported in VIs that run in a web application 1852 attr1852.html

On an S Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

In physical channel names, cDAQ1Mod1 is the default device name for a C Series device plugged into a USB or Standalone CompactDAQ chassis, where cDAQ1 is the default chassis device name, and Mod1 refers ...

If you do not explicitly specify the input or output terminal configuration when you create a channel, NI-DAQmx automatically determines the default terminal configuration at run time. The following table ...

Two NI-DAQmx Read attributes/properties allow you to check if the PLL was unlocked during data acquisition for a task. The first is PLL.UnlockedChansExist. This attribute/property returns a Boolean true ...

On a DSA device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is generated from the internal calibration multiplexer. The channels available on this multiplexer ...

Showing 121-140 of 2179 results
7 of 109 pages