On an X Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

Use the DAQmx - Data Acquisition Nodes with NI-DAQmx hardware devices to develop instrumentation, acquisition, and control applications. Refer to your readme file for a complete listing of devices that ...

Adjusts the internal and external calibration constants for an NI 4204 device. You must connect a known voltage to the device and specify that voltage with reference voltage. LabVIEW NXG does not support ...

Creates channel(s) to generate digital pulses defined by the number of timebase ticks that the pulse is at a high state and the number of timebase ticks that the pulse is at a low state. The pulses appear ...

Adjusts the external calibration constants for the analog output section of a DSA device. You must use the device to generate a high voltage and low voltage at a specified gain, measure the high and low ...

Creates channel(s) that use an RTD to measure temperature. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Temperature-RTD).vi :/lvdaqmx.chm::/DAQmx ...

Routes a control signal to the terminal you specify. The output terminal can reside on the device that generates the control signal or on a different device. You can use this node to share clocks and triggers ...

Configures the expiration states for a digital watchdog timer task. The DAQmx Watchdog properties contain additional watchdog timer configuration options. LabVIEW NXG does not support FPGA devices Not ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When ...

Creates channel(s) that use a microphone to measure sound pressure. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Reads one or more pairs of pulse high and low tick counts from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter 1D ...

Gets the power up states for digital physical lines. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get Power Up States (Digital).vi :/lvdaqmx.chm::/DAQmx ...

Sets the resistor level to pull up or pull down for lines when they are in tristate logic. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up ...

Creates channel(s) that use a Wheatstone bridge to measure pressure. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Updates power up states for analog physical channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Analog).vi :/lvdaqmx.chm::/DAQmx ...

Reads one or more unscaled 32-bit signed integer samples from a task that contains one or more analog input channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Writes data from a 1D array of 8-bit unsigned integers to the TEDS sensor. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Write TEDS Data (U8 Array).vi ...

Writes a floating-point sample to a task that contains a single analog output channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Write (Analog DBL ...

Indicates if the sample clock timing type is supported for the digital output physical channel. Not supported Not supported in VIs that run in a web application 29A8 attr29A8.html