Specifies the acquired values collected when verifying the calibration. NI-DAQmx stores these values as a record of calibration accuracy and does not use them in the scaling process. Refer to the DAQmx ...

Specifies the reference values collected when verifying the calibration. NI-DAQmx stores these values as a record of calibration accuracy and does not use them in the scaling process. Refer to the DAQmx ...

Specifies the units to use to return charge measurements from the channel. Not supported Not supported in VIs that run in a web application From Custom Scale 10065 Units a custom scale specifies. If you ...

Specifies the coupling for the channel. Not supported Not supported in VIs that run in a web application AC 10045 Remove the DC offset from the signal. DC 10050 Allow NI-DAQmx to measure all of the signal. ...

Specifies the units to use to return current RMS measurements from the channel. Not supported Not supported in VIs that run in a web application Amps 10342 Amperes. From Custom Scale 10065 Units a custom ...

Indicates the manufacturer ID of the sensor. Not supported Not supported in VIs that run in a web application 21DA attr21DA.html

Specifies the polarity of the exported Advance Complete Event. Not supported Not supported in VIs that run in a web application Active High 10095 High state is the active state. Active Low 10096 Low state ...

Specifies in what units to generate voltage on the channel. Write data to the channel in the units you select. Not supported Not supported in VIs that run in a web application Volts 10348 Volts. From Custom ...

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 222D attr222D.html

Specifies the decibel reference level in the units of the channel. When you read samples as a waveform, the decibel reference level is included in the waveform attributes. Not supported Not supported in ...

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 2230 attr2230.html ...

Specifies the units for AI.Velocity.IEPESensor.Sensitivity. Not supported Not supported in VIs that run in a web application mVolts/mm/s 15963 Millivolts per millimeter per second. mVolts/in/s 15964 Millivolts ...

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Specifies on which edge of a digital signal to arm the task for a Start Trigger. Not supported Not supported in VIs that run in a web application Rising 10280 Rising edge(s). Falling 10171 Falling edge(s). ...

Specifies the name of a terminal where there is a digital signal to use as the source of the Arm Start Trigger. Not supported Not supported in VIs that run in a web application 1417 attr1417.html

Indicates the name of the internal Arm Start Trigger terminal for the task. This property does not return the name of the trigger source terminal. Not supported Not supported in VIs that run in a web application ...

Specifies on which edge of the second signal to stop each measurement. Not supported Not supported in VIs that run in a web application Rising 10280 Rising edge(s). Falling 10171 Falling edge(s). 834 attr834.html ...

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 21F8 attr21F8.html

Specifies the input terminal of the signal to measure. Not supported Not supported in VIs that run in a web application 2F14 attr2F14.html

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 2200 attr2200.html