Filtered Results

Creates a virtual channel, or set of virtual channels, and adds them to a task. If you use this node within a loop without specifying a task in, the software creates a new task in each iteration of the ...

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors whose specifications provide a polynomial to convert electrical values to physical values. When ...

Contains a Register for Events function, an Event structure, and a DAQmx Task Name constant. You must register the DAQmx event you want to use and configure the Event structure to handle that event. You ...

Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9775 Calibration ...

Reads a single pair of pulse high and low tick counts from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter Pulse Ticks ...

Creates a custom scale that scales values proportionally from a range of pre-scaled values to a range of scaled values. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates a custom scale that uses an nth order polynomial equation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Scale (Polynomial).vi :/lvdaqmx.chm::/DAQmx ...

Creates a custom scale that maps an array of pre-scaled values to an array of corresponding scaled values. NI-DAQmx applies linear interpolation to values that fall between the values in the table. LabVIEW ...

Creates and configures a custom scale. Apply custom scales to input and output channels to provide additional scaling.

Creates a task and adds virtual channels to that task if you specify them in the global virtual channels input. If you specify a task to copy, this node duplicates the configuration of the specified task ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 32-bit unsigned integer samples from a task. Use this instance with devices that use 32-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 8-bit unsigned integer samples from a task. Use this instance with devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Starts an external calibration session on a device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Initialize External Calibration.vi :/lvdaqmx.chm::/mxinitextcal.html ...

Creates and configures a task that controls the watchdog timer of a device. The timer activates when you start the task. Use the digital physical channel expiration states input to set expiration states ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Performs shunt calibration for the specified channels using a strain gage sensor. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Perform Shunt Calibration ...

Creates channel(s) to measure current. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Current-Basic).vi :/lvdaqmx.chm::/DAQmx ...

Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9250 Calibration ...

Deletes the specified task from MAX. This node does not clear the copy of the task stored in memory. Use the DAQmx Clear Task node to clear that copy of the task. LabVIEW NXG does not support FPGA devices ...

Showing 121-140 of 1955 results
7 of 98 pages