Filtered Results

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 2274 attr2274.html ...

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 21FC attr21FC.html

Specifies the logic level behavior on the input line. Not supported Not supported in VIs that run in a web application Logic Level Pull-up 16064 High logic. None 10230 Supply no excitation to the channel. ...

Writes a single sample of Boolean values to a task that contains a single digital output channel. The channel can contain one or more digital lines. LabVIEW NXG does not support FPGA devices Not supported ...

Specifies an array of coefficients for the polynomial that converts physical values to electrical values. Each element of the array corresponds to a term of the equation. For example, if index three of ...

Indicates the coefficients of a linear equation that NI-DAQmx uses to scale values from a voltage to the native format of the device. Each element of the array corresponds to a term of the equation. The ...

Specifies the kind of the waveform to generate. Not supported Not supported in VIs that run in a web application Sine 14751 Sine wave. Triangle 14752 Triangle wave. Square 14753 Square wave. Sawtooth 14754 ...

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 21EA attr21EA.html ...

Specifies in seconds the length of time to measure the frequency of the signal if CI.Freq.MeasMeth is High Frequency with 2 Counters. Measurement accuracy increases with increased measurement time and ...

Specifies the terminal to which signal A is connected. Not supported Not supported in VIs that run in a web application 30DD attr30DD.html

Specifies how to count and interpret the pulses the encoder generates on signal A and signal B. X1, X2, and X4 are valid for quadrature encoders only. Two Pulse Counting is valid for two-pulse encoders ...

Specifies in seconds the amount of time to offset the exported Sample clock. Refer to timing diagrams for generation applications in the device documentation for more information about this value. Not ...

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 221E attr221E.html

Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 221F attr221F.html

Specifies in hertz the rate of the pulse width filter timebase. NI-DAQmx uses this value to compute settings for the filter. Not supported Not supported in VIs that run in a web application 2221 attr2221.html ...

Specifies the input terminal of the signal to use as the timebase of the pulse width filter. Not supported Not supported in VIs that run in a web application 2220 attr2220.html

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Indicates in bytes the size of a raw sample from the task. Not supported Not supported in VIs that run in a web application 217A attr217A.html

Indicates in bytes the required size of a raw sample to write to the task. Not supported Not supported in VIs that run in a web application 217D attr217D.html

Specifies the polarity of the exported Ready for Start Event. Not supported Not supported in VIs that run in a web application Active High 10095 High state is the active state. Active Low 10096 Low state ...

Specifies the terminal to which to route the Ready for Start Event. Not supported Not supported in VIs that run in a web application 1609 attr1609.html

Specifies when the ready for transfer event deasserts. Not supported Not supported in VIs that run in a web application Onboard Memory More than Half Full 10237 Deassert the signal when more than half ...

Specifies in samples the threshold below which the Ready for Transfer Event deasserts. This threshold is an amount of space available in the onboard memory of the device. RdyForXferEvent.DeassertCond must ...

Specifies the polarity of the exported Sample Clock if SampClk.OutputBehavior is Pulse. Not supported Not supported in VIs that run in a web application Active High 10095 High state is the active state. ...

Specifies the sampling rate in samples per channel per second. If you use an external source for the Sample Clock, set this input to the maximum expected rate of that clock. Not supported Not supported ...

Specifies the terminal of the signal to use as the Sample Clock. Not supported Not supported in VIs that run in a web application 1852 attr1852.html

Indicates the name of the internal Sample Clock terminal for the task. This property does not return the name of the Sample Clock source terminal specified with SampClk.Src. Not supported Not supported ...

Specifies on which edge to recognize a Sample Clock Timebase pulse. This property is useful primarily when the signal you use as the Sample Clock Timebase is not a periodic clock. Not supported Not supported ...

Specifies the number of pulses of the Master Timebase needed to produce a single pulse of the Sample Clock Timebase. The rate of the Sample Clock Timebase is equal to (frequency of Master Timebase) / (value ...

Showing 151-180 of 2179 results
6 of 73 pages