Specifies which shunt calibration switch(es) to enable. Use AI.Bridge.ShuntCal.Enable to enable the switch(es) you specify with this property. Not supported Not supported in VIs that run in a web application ...

Indicates whether the global channel can be edited in the DAQ Assistant. Not supported Not supported in VIs that run in a web application 22D1 attr22D1.html

Specifies in ohms the desired value of the internal shunt calibration A resistor. Not supported Not supported in VIs that run in a web application 2F78 attr2F78.html

Specifies whether to use internal or external shunt when Shunt Cal A is selected. Not supported Not supported in VIs that run in a web application Built-In 10200 Use the internal shunt. User Provided 10167 ...

Specifies in ohms the actual value of the internal shunt calibration B resistor. Not supported Not supported in VIs that run in a web application 2F7B attr2F7B.html

Indicates the names of all devices installed in the system. Not supported Not supported in VIs that run in a web application 193B attr193B.html

Indicates an array that contains the names of all global channels saved on the system. Not supported Not supported in VIs that run in a web application 1265 attr1265.html

Indicates the major portion of the installed version of NI-DAQmx, such as 7 for version 7.0. Not supported Not supported in VIs that run in a web application 1272 attr1272.html

Indicates the minor portion of the installed version of NI-DAQmx, such as 0 for version 7.0. Not supported Not supported in VIs that run in a web application 1923 attr1923.html

Indicates an array that contains the names of all custom scales saved on the system. Not supported Not supported in VIs that run in a web application 1266 attr1266.html

Indicates an array that contains the names of all tasks saved on the system. Not supported Not supported in VIs that run in a web application 1267 attr1267.html

Specifies the first physical value, corresponding to AI.Bridge.TwoPointLin.First.ElectricalVal. Specify this value in the unit indicated by AI.Bridge.PhysicalUnits. Not supported Not supported in VIs that ...

Specifies the terminal to which to route the 10MHz Clock. Not supported Not supported in VIs that run in a web application 226E attr226E.html

Specifies the second physical value, corresponding to AI.Bridge.TwoPointLin.Second.ElectricalVal. Specify this value in the unit indicated by AI.Bridge.PhysicalUnits. Not supported Not supported in VIs ...

Indicates if any device(s) in the task detected the insertion or removal of an accessory since the task started. Reading this property clears the accessory change status for all channels in the task. You ...

Specifies whether to apply the channel calibration to the channel after the expiration date has passed. Not supported Not supported in VIs that run in a web application 2299 attr2299.html

Specifies whether to apply the pulse width filter to the signal. Not supported Not supported in VIs that run in a web application 2238 attr2238.html

Specifies the description entered for the calibration of the channel. Not supported Not supported in VIs that run in a web application 22A4 attr22A4.html

Specifies the name of a terminal where there is a digital signal to use as the source of the Advance Trigger. Not supported Not supported in VIs that run in a web application 1362 attr1362.html

Specifies the type of trigger to use to advance to the next entry in a switch scan list. Not supported Not supported in VIs that run in a web application Digital Edge 10150 Advance to the next entry in ...