DSUB or LEMO connectivity Built-in support for accelerometer, powered-sensor, full-bridge, and voltage measurements Support for half-bridge, quarter-bridge, 60 V , and current measurements with adapters ...

RTD R wire R wire NI 9219 EX+ EX- LO R wire Parent topic: Measurement Types Related reference 3-Wire RTD Pinout

2 3 4 5 6 — — EX+ — EX- LO 1 Parent topic: Measurement Type Pinout Related reference 3-Wire RTD Connections

LO HI EX- RTD/ Resistor EX+ R wire R wire R wire R wire NI 9219 I ADC I Parent topic: Measurement Types Related reference 4-Wire Resistance and 4-Wire RTD Pinout

2 3 4 5 6 — — EX+ HI EX- LO 1 Parent topic: Measurement Type Pinout Related reference 4-Wire Resistance and 4-Wire RTD Connections

Make sure that devices you connect to the NI-9219 are compatible with the module specifications. Use shielded cables and twisted pair wiring for the best signal quality. NI recommends using the backshell ...

What to Use NI-9219 spring-terminal connector copper conductor wire with of insulation stripped from the end Flathead screwdriver with a 2.3 mm x 1.0 mm ( 0.09 in. x 0.04 in. ) blade, included with the ...

2 3 4 5 6 — — HI — LO — 1 Parent topic: Measurement Type Pinout Related reference Current Connections

LO HI NI 9219 + – The digital in measurement type is only supported in CompactRIO systems. Tip Visit ni.com/info and enter the Info Code 9219cdaq for information about implementing the digital in measurement ...

2 3 4 5 6 — — — HI LO — 1 Parent topic: Measurement Type Pinout Related reference Digital In Connections

This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable ...

The NI-9219 protects the excitation circuit from overcurrent and overvoltage fault conditions.

LO HI EX- EX+ R wire R 1 R 4 R 2 R 3 R wire NI 9219 Parent topic: Measurement Types Related reference Full-Bridge Pinout

Figure 1. NI 9157/9159 Front Panel 4 6 2 5 1 C C V2 V1 INPUT 9-30 V 35W MAX NO FPGA APP USER FPGA1 USER FPGA2 USER FPGA3 P USER FPGA1 USER FPGA2 USER FPGA3 P OWER USER FPGA1

CompactRIO NI CompactDAQ Located at ni.com/manuals RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Installs with the software NI 9222 Datasheet NI-RIO ...

CompactRIO NI CompactDAQ Located at ni.com/manuals RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Installs with the software NI 9223 Datasheet NI-RIO ...

The NI-9229 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2 , AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations; and nonhazardous locations ...

The NI-9229 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07 ATEX 0626664X and is IECEx UL 14.0089X certified. Each NI-9229 is marked II 3G and is suitable for use in Zone 2 hazardous locations, ...

If hazardous voltages are connected to the product, take the following precautions. A hazardous voltage is a voltage greater than: 30 V RMS , 42.4 V peak , or 60 V DC in DRY LOCATIONS 16 V RMS , 22.6

If your application is subject to high vibration, NI recommends that you follow these guidelines to protect connections to the NI-9229 with screw terminal : Use ferrules to terminate wires to the detachable ...

Some products are approved for marine (shipboard) applications. To verify marine approval certification for a product, visit ni.com/product-certifications , search by model number, and click the appropriate ...

This document explains how to connect to the NI-9229 . Note Before you begin, read the NI-9229 Safety, Environmental, and Regulatory Information document on ni.com/manuals and complete the software and ...

A I 0 + A I 0 – A I 1 + A I1 – AI 2 + AI 2– A I 3 + A I 3 – 0 1 0 1 0 1 0 1 AI0+ AI0- AI1+ AI1-

Ensure that the environment in which you are using the NI-9229 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C Operating humidity (IEC 60068-2-78) ...

Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and compromise the built-in safety protection. Attention Suivez ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

Showing 121-150 of 28316 results
5 of 944 pages