Creates channel(s) to generate digital signals. You can group digital lines into one digital channel or separate them into multiple digital channels. If you specify one or more entire ports in lines input ...

Creates channel(s) to measure strain. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Creates a virtual channel, or set of virtual channels, and adds them to a task. If you use this node within a loop without specifying a task in, the software creates a new task in each iteration of the ...

Creates a custom scale that uses the equation y=mx+b, where x is a pre-scaled value, and y is a scaled value. The equation is identical for input and output. If the equation is in the form x=my+b, you ...

Creates a custom scale that scales values proportionally from a range of pre-scaled values to a range of scaled values. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates a custom scale that maps an array of pre-scaled values to an array of corresponding scaled values. NI-DAQmx applies linear interpolation to values that fall between the values in the table. LabVIEW ...

Performs shunt calibration for the specified channels using a bridge sensor. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Perform Shunt Calibration ...

Updates power up states for analog physical channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Analog With Output Type).vi ...

Sets the digital logic family to use when the device powers up. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Digital Logic Family).vi ...

Routes a control signal to the terminal you specify. The output terminal can reside on the device that generates the control signal or on a different device. You can use this node to share clocks and triggers ...

Configures the task to stop the acquisition when the device acquires all pretrigger samples, matches a digital pattern, and acquires all posttrigger samples. LabVIEW NXG does not support FPGA devices Not ...

Configures the task to stop the acquisition when the device acquires all pretrigger samples, detects a rising or falling edge of a digital signal, and acquires all posttrigger samples. LabVIEW NXG does ...

Configures the task to start acquiring or generating samples when an analog signal crosses the level you specify. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application ...

Updates power up states for digital physical channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Digital).vi :/lvdaqmx.chm::/DAQmx ...

Writes the specified binary value to the DAC on the specified physical channel. This module requires a sweep of DAC values obtained from the DAQmx Get 9265 Calibration Adjustment Points node. LabVIEW NXG ...

Sets an SCXI-1102 module to the specified gain value for calibration. The terminal where you can measure module output depends on the configuration of the module in MAX. National Instruments recommends ...

Writes the specified binary value to the DAC on the specified physical channel at the specified range. Specify at least two calibration points for each physical channel and range you calibrate. Use 0 and ...

Sets an SCXI-1141 module to the specified gain value for calibration. The terminal where you can measure module output depends on the configuration of the module in MAX. National Instruments recommends ...