Filtered Results

Adjusts the external calibration constants for an NI PXIe-4330 or NI PXIe-4331 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 433x Calibration.vi ...

Adjusts the external calibration constants for an NI PXIe-4353 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 4353 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9201 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9201 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Configures TDMS file logging for the task. To maximize performance and to minimize file size, DAQmx TDMS files store raw data and scaling information separately, and do not need defragmentation. Attempting ...

Adjusts the external calibration constants for an SCXI-1143 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 1143 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Alters the state of a task according to the action you specify. If error in indicates that an error occurred previously, this node executes normally if action is unreserve or abort. LabVIEW NXG does not ...

Creates channel(s) that use an RVDT to measure angular position. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates a custom scale that scales values proportionally from a range of pre-scaled values to a range of scaled values. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web ...

Creates channel(s) that use a thermocouple to measure temperature. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not supported ...

Creates channel(s) that use a Wheatstone bridge to measure torque. You must configure the physical channel(s) with TEDS information to use this VI. NI-DAQmx scales electrical values to physical values ...

Creates channel(s) to measure voltage. Use this instance for custom sensors that require excitation. You can use the excitation to scale the measurement. You must configure the physical channel(s) with ...

Creates channel(s) that measure voltage ratios from a Wheatstone bridge. Use this instance with bridge-based sensors that measure phenomena other than strain, force, pressure, or torque, or that scale ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Creates channel(s) that use a frequency-to-voltage converter to measure frequency. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Frequency-Voltage).vi ...

Creates channel(s) that use(s) an RVDT to measure angular position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-RVDT).vi ...

Creates channel(s) to measure resistance. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Resistance).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) to measure strain. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Strain-Strain Gage).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) to generate current. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AO-Current-Basic).vi :/lvdaqmx.chm::/DAQmx ...

Creates channel(s) to generate voltage. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AO-Voltage-Basic).vi :/lvdaqmx.chm::/DAQmx ...

Creates a channel to count the number of rising or falling edges of a digital signal. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a ...

Showing 81-100 of 2160 results
5 of 108 pages