Filtered Results

Specifies a description for the scale. Not supported Not supported in VIs that run in a web application 1226 attr1226.html

Specifies the slope, m, in the equation y=mx+b. Not supported Not supported in VIs that run in a web application 1227 attr1227.html

Specifies the y-intercept, b, in the equation y=mx+b. Not supported Not supported in VIs that run in a web application 1228 attr1228.html

Specifies the largest value in the range of pre-scaled values. NI-DAQmx maps this value to Map.ScaledMax. Not supported Not supported in VIs that run in a web application 1231 attr1231.html

Specifies the smallest value in the range of pre-scaled values. NI-DAQmx maps this value to Map.ScaledMin. Not supported Not supported in VIs that run in a web application 1232 attr1232.html

Specifies the actual amount of excitation supplied by an internal excitation source. If you read an internal excitation source more precisely with an external device, set this property to the value you ...

Specifies the smallest value in the range of scaled values. NI-DAQmx maps this value to Map.PreScaledMin. Reads coerce samples that are smaller than this value to match this value. Writes generate errors ...

Specifies whether this channel will disable excitation after the task is uncommitted. Setting this to Zero Volts or Amps disables excitation after task uncommit. Setting this attribute to Maintain Existing ...

Specifies whether to use local or remote sense to sense excitation. Not supported Not supported in VIs that run in a web application Local 16095 Local. Remote 16096 Remote. 30FD attr30FD.html

Specifies the source of excitation. Not supported Not supported in VIs that run in a web application Internal 10200 Use the built-in excitation source of the device. If you select this value, you must ...

Specifies if the SCXI-1122 multiplexes the excitation to the upper half of the channels as it advances through the scan list. Not supported Not supported in VIs that run in a web application 2180 attr2180.html ...

Indicates the method or equation form that the custom scale uses. Not supported Not supported in VIs that run in a web application Linear 10447 Scale values by using the equation y=mx+b, where x is a prescaled ...

Specifies in volts the output voltage of the bridge while not under load. NI-DAQmx subtracts this value from any measurements before applying scaling equations. If you set AI.Bridge.InitialRatio, NI-DAQmx ...

Specifies in ohms the resistance of the bridge while not under load. Not supported Not supported in VIs that run in a web application 17EC attr17EC.html

Specifies the saved global channel to which subsequent properties apply. Not supported Not supported in VIs that run in a web application 22CF attr22CF.html

Specifies an array of coefficients for the polynomial that converts electrical values to physical values. Each element of the array corresponds to a term of the equation. For example, if index three of ...

Specifies the saved task to which subsequent properties apply. Not supported Not supported in VIs that run in a web application 22CB attr22CB.html

Indicates whether the task can be deleted through MAX. Not supported Not supported in VIs that run in a web application 22CE attr22CE.html

Specifies whether to enable a shunt calibration switch. Use AI.Bridge.ShuntCal.Select to select the switch(es) to enable. Not supported Not supported in VIs that run in a web application 94 attr94.html ...

Indicates whether the custom scale can be deleted through MAX. Not supported Not supported in VIs that run in a web application 22D6 attr22D6.html

Showing 81-100 of 2088 results
5 of 105 pages