You can create a number of different types of virtual channels, depending on the signal type—analog, digital, or counter—and direction (input or output). These channels can be either global virtual channels ...

You might need to call the Wait Until Done function/VI to ensure that the specified operation is complete before you stop the task. The most common example is a finite generation. If you start a task that ...

If the measurement or generation is finite, the task is done when you acquire or generate the final sample or when you call the Stop Task function/VI. If the measurement or generation is continuous (including ...

Adjusts the external calibration constants for an NI 9229 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9229 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9230 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9230 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration constants for an NI 9232 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9232 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Adjusts the external calibration gain constants for an NI 9234 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9234 Gain Calibration.vi ...

Adjusts the external calibration offset constants for an NI 9234 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9234 Offset Calibration.vi ...

Adjusts the external calibration constants for an NI 9238 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9238 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Use the DAQmx - Data Acquisition Nodes with NI-DAQmx hardware devices to develop instrumentation, acquisition, and control applications. Refer to your readme file for a complete listing of devices that ...

Adjusts the external calibration constants for an NI 9246 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9246 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Creates a channel that uses a linear encoder to measure linear position. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this ...

Adjusts the external calibration constants for an NI 9251 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9251 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Clears the task. Before clearing, this node aborts the task, if necessary, and releases any resources the task reserved. You cannot use a task after you clear it unless you recreate the task. If you use ...

Removes TEDS information from the physical channel you specify. This node temporarily overrides any TEDS configuration for the physical channel that you performed in MAX. LabVIEW NXG does not support FPGA ...

Closes an open external calibration session. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Close External Calibration.vi :/lvdaqmx.chm::/mxcloseextcal.html ...

Adjusts the external calibration constants for an NI 9265 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9265 Calibration.vi :/lvdaqmx.chm::/DAQmx ...

Computes a set of coefficients for a polynomial that approximates the inverse of the polynomial with the coefficients you specify with the coefficients input. This VI generates a table of x versus y values ...

Configures TDMS file logging for the task. To maximize performance and to minimize file size, DAQmx TDMS files store raw data and scaling information separately, and do not need defragmentation. Attempting ...

Associates TEDS information with the physical channel you specify. If you do not specify the filename of a data sheet in the virtual TEDS file input, this node attempts to find a TEDS sensor connected ...