When I insert my PXI card into my system, it appears in NI Measurement & Automation Explorer (NI MAX) as a PCI card.

I am recording measurements from a multifunction I/O device. Currently, Iam using the DAQ Assistant to read a number of samples and output them on a graph. This happens inside a loop to read samples continuously. ...

I am running an application that is working with other cards in other computers. When I run it on this computer I get Error-200478 DAQmx Start Task.vi: 1Task Name: _unnamedTask<8>for an ...

What is the difference between the sample clock (scan clock) and the convert clock (channel clock) on my multifunction data acquisition board?

I have one or more channels on my DAQ device not connected to any signal or sensor or the device is disconnected from the computer. Why are all of thechannels reading the same value? Why are my channels/signals ...

The following devices support programmable power up states: 6509 651x (6512, 6513, 6514, 6515) 652x (6525, 6527, 6528), All M Series boards (62xx) All X Series boards (63xx) You can set power-up states ...

I am using a NI X-series DAQ hardware, why do I get high output in the DIO lines during the computer powering up state or after computer is shut down. Can this be changed?

I have two I/O devices of the same type (i.e. two sinking or two sourcing ones). I want to connect them together. Is that possible? Does my sinking output device require an external voltage source?

I am using multifunction I/O DAQ device. When I measure sine wave whose frequency is 500 kHz and the peak is 1 V, I found that the measured value has lower peak though I could measure 1 V level signal ...