If your application is subject to high vibration, NI recommends that you use the NI-9940 backshell kit to protect connections to the NI-9213 . Parent topic: Overview

The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted. The specifications are for the NI 9214 used in conjunction with an TB-9214 . Caution Do not operate the NI-9214 ...

The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted. Accuracy within typical use can vary based on chassis, mounting parameters, other modules present in the system, ...

This document explains how to connect to the NI-9215 . In this document, the NI-9215 with screw terminal , NI-9215 with spring terminal , and NI-9215 with BNC are referred to inclusively as the NI-9215 ...

If you need to clean the module, wipe it with a dry towel. Tip For two-dimensional drawings and three-dimensional models of the C Series module and connectors, visit ni.com/dimensions and search by module ...

AI0+ AI0- AI1+ AI1– AI2+ AI2– AI3+ AI3– NC COM 0 1 2 3 4 5 6 7 8 9 AI0+ AI0– AI1+ AI1– AI2+ AI2– AI3+ AI3– NC COM 0 1 2 3 4 5 6 7 8 9

Ensure that the environment in which you are using the NI 9215 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C Operating humidity (IEC 60068-2-78) ...

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications ...

What to Use TB-9212 with mini TC Shielded thermocouple Clamp-on ferrite bead (part number 781233-01 ) What to Do Plug the thermocouple into the thermocouple input on the TB-9212 with mini TC . Install ...

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No. ...

Connect only voltages that are within the following limits. Channel-to-COM ±30 V maximum Isolation Channel-to-channel None Channel-to-earth ground Continuous 250 V RMS, Measurement Category II Withstand ...

+ – AI+ AI– Voltage Source NI 9215 with Screw/Spring Terminal COM Connect the ground signal to COM to keep the signal source within the common-mode voltage range. NI 9215 with BNC AI+ AI– + – Voltage Source ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

AI0 AI1 AI2 AI3 AI4 AI5 AI6 AI7 NC COM 0 1 2 3 4 5 6 7 8 9 COM NC COM COM NC COM COM NC COM COM NC COM COM AI0 NC AI1 AI2 NC AI3 AI4

Ensure that the environment in which you are using the NI-9221 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C Operating humidity (IEC 60068-2-78) ...

Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and compromise the built-in safety protection. Attention Suivez ...

Connect only voltages that are within the following limits. Channel-to-COM ±60 V DC maximum Channel-to-channel None Channel-to-earth ground Continuous 250 V RMS, Measurement Category II Withstand 2,300 ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

This document explains how to connect to the NI-9218 . In this document, the NI-9218 with LEMO and the NI-9218 with DSUB are referred to inclusively as the NI-9218 . Note Before you begin, read the NI-9218 ...

5 4 3 2 1 9 8 7 6 V – + V 5 4 3 2 1 9 8 7 6 4 5 1 8 3 2 1 0 9 6 7 V+ V- V+ V- 4 5 1

Ensure that the environment in which you are using the NI 9218 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C Operating humidity (IEC 60068-2-30) ...

NI 9218 NI 9984/9985 DSUB/LEMO RC EXC AI Connecting 120 Ω quarter bridges requires the NI 9984 . Connecting 350 Ω quarter bridges requires the NI 9985 . Tip NI recommends 2 V excitation when using a NI ...

Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and compromise the built-in safety protection. Attention Suivez ...

Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples. Visit ni.com/services to learn ...

TEDS Enabled Sensor NI 9218 T+ T- Data COM For more information about TEDS, visit ni.com/info and enter the Info Code rdteds . Parent topic: Overview

TEDS Class 1 sensors provide an interface for transferring information from sensors. The NI 9218 with LEMO , NI 9218 with DSUB , NI 9982L , NI 9982D , NI 9982F support TEDS Class 1 sensors. TEDS Class ...

V sup- V sup+ V sup + V sup - NI 9218 with LEMO V sup- V sup+ V sup + V sup - NI 9218 with LEMO V sup- V sup+ NI 9218 with LEMO V sup + V

Showing 91-120 of 28307 results