Filtered Results

Creates channel(s) that use a Wheatstone bridge to measure force or load. Use this instance with sensors, whose specifications do not provide a polynomial for scaling, or a table of electrical and physical ...

Creates a virtual channel, or set of virtual channels, and adds them to a task. If you use this node within a loop without specifying a task in, the software creates a new task in each iteration of the ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 8-bit unsigned integer samples from a task. Use this instance with devices that use 8-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads an array of Boolean values from a task that contains a single digital input channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Digital ...

Configures when the DAQ device transfers data to a peripheral device, using the onboard Sample Clock of the DAQ device to control burst handshake timing, and exporting that clock for use by the peripheral ...

Updates power up states for digital physical channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Digital).vi :/lvdaqmx.chm::/DAQmx ...

Starts a new TDMS file the next time data is written to disk. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Start New File.vi :/lvdaqmx.chm::/mxstartnewfile.html ...

Writes a single Boolean sample to a task that contains a digital output channel composed of a single line. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx ...

Creates channel(s) that use a thermistor to measure temperature. Use this instance when the thermistor requires current excitation. LabVIEW NXG does not support FPGA devices Not supported in VIs that run ...

Specifies the names of the digital lines or ports on which to detect rising edges. The lines or ports must be used by virtual channels in the task. You also can specify a string that contains a list or ...

Specifies the logic level behavior on the count reset line. Not supported in VIs that run in a web application Logic Level Pull-up 16064 High logic. None 10230 Supply no excitation to the channel. 30B2 ...

Specifies the terminal of the signal to use as the timebase of the digital filter. Not supported in VIs that run in a web application 2F18 attr2F18.html

On an S Series device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is being generated from the internal calibration multiplexer. The channels available ...

Quantization error is the inherent uncertainty in digitizing an analog value as a result of the finite resolution of the conversion process. Quantization error depends on the number of bits in the converter, ...

Use the DAQmx - Data Acquisition Nodes with NI-DAQmx hardware devices to develop instrumentation, acquisition, and control applications. Refer to your readme file for a complete listing of devices that ...

Converts a comma-delimited list, or range of physical or virtual channels, into an array of physical or virtual channel names. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in ...

Indicates if the sample clock timing type is supported for the digital output physical channel. Not supported in VIs that run in a web application 29A8 attr29A8.html

Indicates the model number of the sensor. Not supported in VIs that run in a web application 21DB attr21DB.html

Showing 61-80 of 1955 results
4 of 98 pages