Configures the task to stop the acquisition when the device acquires all pretrigger samples, matches a digital pattern, and acquires all posttrigger samples. LabVIEW NXG does not support FPGA devices Not ...
Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9250 Calibration ...
Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9251 Calibration ...
Reads one or more unscaled 32-bit unsigned integer samples from one or more counter tasks. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter ...
Disables reference triggering for the measurement. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Reference Trigger (None).vi :/lvdaqmx.chm::/DAQmx ...
Returns the reference voltage values to be measured by a reference device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9263 Calibration Adjustment ...
Configures a task to start acquiring or generating samples when a digital pattern is matched. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Start Trigger ...
Reads one or more pairs of pulse high and low times from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter 1D Pulse ...
Reads a single pair of pulse high and low tick counts from a counter input task. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Counter Pulse Ticks ...
Reads one or more raw, 16-bit signed integer samples from a task. Use this instance with devices that use 16-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...
Measures the onboard reference voltage of the device, and adjusts the self-calibration constants, to account for any errors caused by short-term fluctuations in the operating environment. When you self-calibrate ...
Gets the power up states for digital physical lines. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get Power Up States (Digital).vi :/lvdaqmx.chm::/DAQmx ...
Updates power up states for analog physical channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Analog).vi :/lvdaqmx.chm::/DAQmx ...
Gets the resistor level for lines when they are in tristate logic. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get Power Up States (Digital Pull Up ...
Returns the power up states that physical channels on a device are set to when the device powers up or when you reset the device. This node returns data for only one line.
Reads an array of Boolean values from a task that contains a single digital input channel. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Read (Digital ...
Starts an external calibration session on a device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Initialize External Calibration.vi :/lvdaqmx.chm::/mxinitextcal.html ...